Technical Specification Measuring Principle
Ignitability from small flame source
Cabinet Dimensions (exterior) 700mm (W) x 400mm (D) x 800mm (H) System Dimensions Sample holder
Anemometer Stopwatch
Services Test Room
Gas Supply Hood ± 0.1 m/s accuracy Accuracy better than 1 second in 60 minutes 1500mm (W) x 1200mm (D) x 900mm (H)
Standard holder and holder for products which melt or shrink included
The ignitibility apparatus should be situated in a draught free environment at 23 ± 5°C and a relative humidity of 50 ± 20%.
A supply of natural gas of minimum 95% purity. In order to obtain flame stability the gas pressure shall be between 10kPa and 50kPa.
The combustion chamber should be situated under a suitable extraction system.
Due to the continuous development policy of FTT technical changes could be made without prior notice.
Other Euroclass Test Methods Detailed product catalogues are also available for:
Single Burning Item EN 13823 Reaction to fire tests for building products excluding floorings exposed to thermal attack by a single burning item, the SBI
Oxygen Bomb Calorimeter EN ISO 1716 Reaction to fire tests for building products – Determination of the heat of combustion.
Non Combustibility Apparatus EN ISO 1182 Reaction to fire tests for building products – Non combustibility test.
Flooring Radiant Panel EN ISO 9239-1 Reaction to fire tests for building products – Horizontal surface spread of flame for floor coverings.