Sample processing modules New sample prep stations from GERSTEL (Linthicum, Md.) include the QuickMix for stir- ring samples in vials from 2 to 20 mL, with an optional vial heater. The CCD cryostatic cooling station is designed to quickly cool samples and traps as low as –40 °C. Actual temperature is reported to the software for recordkeeping. A dual-camera system images barcodes on vials and plates in the SID barcode reader.
GERSTEL focused on new stations for its MPS roboticpro
workstation, such as an SPME pack-
age that includes a new injection liner which fits into the GERSTEL CIS inlet, thus avoiding septa-associated artifacts. The MPS roboticpro can also derivatize a sample on an SPME needle and is controlled with an intuitive graphical human interface.
Gas generators for GC and GC/MS GCs may require a variety of gases for the carrier gas and detectors. Quadrex Corp.’s (Bethany, Conn.) GASTRAP self-regenerating gas purifi ers for GC improve purity by a factor of 10, e.g., 15 ppm to <1 ppm (or 99.999%) (see
Ensure consistent, high quality pharmaceutical products.
Figure 4). Thus, it is possible to start with lower-cost gases and upgrade them to 5 nines (99.999%) while eliminating gas line fi lters en- tirely. The purifi cation utilizes pressure swing adsorption to adsorb gases at high pressure and diff erentially release them as the pressure is reduced. Sorbents include zeolites and acti- vated carbon.
The Hydrogen and Hydrogen + Leak unit deliver fi ve nines hydrogen by removing
oxygen, nitrogen, carbon dioxide, hydrocarbons and moisture. The + Leak accessory termi- nates hydrogen fl ow exceeding 450 mL/min for 5 minutes. This also triggers an audible warning. If the fl ow is higher than 1 L/min, it is stopped immediately.
For nitrogen, the Quadrex GT-N2 and the GT- ZN2 selectively trap oxygen, water, carbon dioxide and hydrocarbons from an existing
DMA Family- World’s Most Accurate
Figure 4 – GASTRAP helium purifi er and GC column from Quadrex Corp. (Image courtesy of Quadrex Corp.)
AMERICAN LABORATORY
Density Meters Get in touch
19 MAY 2016
- R & D requiring the highest accuracy - QC checks on raw materials
- Ensure compliance with Pharmaceutical Qualification Packages
- Automation options available
www.anton-paar.com
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60