so that the head of the bolt is pulled down, the spring will be compressed. If the nut is rotated so that 2 force units are indicated on the casing, the compressive force acting on the spring will be 2 and the tensile force in the bolt shank will also be 2. This is illustrated in figure 8; this is like a tightened bolt without any working load applied. If a weight is now added to the


Figure 8


bracket (figure 9) of value 1, then the initial reaction is to think


that the load in the bolt must increase, otherwise what happens to the additional force? Surprisingly it will keep at its existing value of 2 - it will not ‘feel’ any of the additional force. To visualise why this is so - imagine what would happen if the load in the bolt did increase. To do this it would compress the spring more and a gap would be made between the bracket and the plate. If such a gap was to form then it would mean that there would be 2 units of force acting upwards - due to the spring, and 1 unit of force acting downwards from the applied weight. Clearly this force imbalance would not occur. What does happen is that the effect of the applied load is to decrease the clamp force that exists between the plate and the bracket. With no load applied, the clamp force is 2 units and with the load applied this decreases to 1 unit of force. The bolt would not actually ‘feel’ any of the applied force until it exceeded the bolts clamp force. Figure 10 shows the condition when


Figure 9 Figure 10


a load of 3 is applied. The joint will separate and the 3 units of weight acting down will be balanced by the 3 units of force in the spring. The point of joint separation, from a design perspective, is usually taken as the point at which the joint will have a finite length. Besides sustaining the full applied loading there are usually bending forces induced into the bolt because of eccentricity of the applied loading. Repeatedly applied this


will rapidly lead to fatigue failure of the bolt. Older design procedures proposed calculation methods based upon the idea that the bolt will not ‘feel’ any of the applied load until it exceeds the bolts clamp force. That is, the bolt should be sized so that its clamp force is equal to the external load after a factor of safety has been included. Practical fasteners differ from that shown in figure 2 in that elongation of the fastener and compression of the clamped parts occurs upon tightening. This compression results in the bolt sustaining a proportion of the applied load. The actual amount of the load being sustained being dependent upon the relative stiffness of the bolt to the clamped material. In actual practice, the bolt will sustain a proportion of the


applied loading prior to the joint separating. This is due to the joint compressing, as well as the bolt extending, when tightened. This is illustrated in figure 11. When


the loading is applied, the compression of the joint is reduced. This, in turn, increases the distance between the two joint faces which, in turn, increases the loading on the bolt. The bolt and joint stiffness can be computed and, from this, the proportion of the load sustained by the bolt and the amount that the joint compression is reduced can also be computed. The key aspect of the success or otherwise of the majority of bolted joints is the residual loading that acts on the joint interface. That is, will joint separation or joint movement occur when loading is applied? As the applied load acting on the joint increases, the force clamping the joint together decreases. If the clamping force decreases to zero as a result of the applied load, the bolt will have to totally sustain any subsequent increase in this load. Research has shown that bolted joints usually fail as a result of the applied forces acting on the joint decreasing the clamp force, present between the joint layers, to below a required level. Failure can include leakage from a joint (if it contains a gasket) or the bolts coming loose or failing due to fatigue. Initially it may appear that the joint failure is not due to insufficient clamp force, but a more detailed analysis often shows that this is indeed the cause rather than defective or sub-standard bolts or the bolts sustaining too much load. Many applications require that the plates comprising the joint be clamped together tightly so that any possible movement is prevented. Effectively the plates are prevented from moving by friction increased by the bolt’s clamp force. In such applications, a level of clamp force must be maintained in order that movement is prevented. If the clamp force reduces to below this level, joint movement can be caused that dramatically increases embedding (plastic deformation under the nut/bolt head) resulting in the bolt quickly losing preload and then loosening or failing by fatigue. If the joint contains a gasket, a minimum level of clamp force is usually required in order that leakage is prevented and the sealing function is maintained. Maintaining a high initial bolt preload is essential to ensuring that a bolted joint will survive.


Figure 11


Prior to forming his company, Bolt Science in 1992, Bill’s original background was in design engineering. The company is a provider of independent technical expertise in bolted joint technology. He is a chartered engineer and has a Doctorate in Engineering on the self-loosening of threaded fasteners. Bill has delivered training courses around the world on the analysis of bolted joints and bolting technology.


114 Fastener + Fixing Magazine • Issue 72 November 2011


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88  |  Page 89  |  Page 90  |  Page 91  |  Page 92  |  Page 93  |  Page 94  |  Page 95  |  Page 96  |  Page 97  |  Page 98  |  Page 99  |  Page 100  |  Page 101  |  Page 102  |  Page 103  |  Page 104  |  Page 105  |  Page 106  |  Page 107  |  Page 108  |  Page 109  |  Page 110  |  Page 111  |  Page 112  |  Page 113  |  Page 114  |  Page 115  |  Page 116  |  Page 117  |  Page 118  |  Page 119  |  Page 120  |  Page 121  |  Page 122  |  Page 123  |  Page 124  |  Page 125  |  Page 126  |  Page 127  |  Page 128  |  Page 129  |  Page 130  |  Page 131  |  Page 132  |  Page 133  |  Page 134  |  Page 135  |  Page 136  |  Page 137  |  Page 138  |  Page 139  |  Page 140  |  Page 141  |  Page 142  |  Page 143  |  Page 144  |  Page 145  |  Page 146  |  Page 147  |  Page 148  |  Page 149  |  Page 150  |  Page 151  |  Page 152  |  Page 153  |  Page 154  |  Page 155  |  Page 156