The Addenbrooke’s Hospital
site in Cambridge could
double in size
Partnership
Preparing for
the 2020 Vision
Addenbrooke’s
Hospital, along with
the Rosie Maternity
Hospital on the same
site, is operated by
Cambridge University
Hospitals, an NHS
Foundation Trust
with a mix of clinical,
biomedical and
research functions. It
currently has more than
1,000 beds and around
7,000 staff.
As part of its ‘2020
Vision’, the trust
intends to extend the
site on the southern
fringe of the hospital
– the South Campus
Hospital Renewal
indeed, 78 per cent of carbon emissions within the of hospitals, this is something that will impinge upon
Programme – while
NHS come from ancillary services such as transport other hospital expansion plans.
also including
and procurement. The redevelopment of the hospital, The existing Addenbrooke’s site currently uses a
other significant
therefore, will facilitate reductions in ancillary carbon steam distribution system, dating back to the 1960s,
developments in the
emissions, the trust says. with some more recent modifications, to provide
master plan.
heating, humidification, hot water and sterilisation
This plan needs to
Heat and power functions. Steam is raised in a central energy centre
consider the impact of
The complexity of the master plan is exemplified by comprising four levels with a gross floor area of circa
any extension work on
the considerations that need to be given to the heating 2,000 sq m containing gas boilers, a gas CHP unit,
the existing services
and power generation aspects of the site. Given the and two incinerators.
and utility infrastructure
extensive heating networks operated by the majority The waste incineration plant is central to the trust’s >
as well as potential
for the ongoing site
development.
NHS carbon emissions and reduction targets (in million tonnes) in England
Consulting engineers
25.00
AECOM (formerly Faber
Maunsell) was engaged
NHS England
to provide overarching
NHS England forecast
engineering strategies
2007 baseline
20.00
Carbon Reduction Strategy Target
that support the master
10% target from 2007 baseline
planning proposals,
1990 baseline
as part of a master
Climate Change Act target
planning group led by
15.00
26% target from 1990 baseline a combined architect
64% target from 1990 baseline
team of Devereux and
80% target from 1990 baseline
Allies & Morrison.
Ml CO2
10.00
AECOM’s
input includes
environmental, energy
and sustainability
5.00 issues, engineering
services infrastructure,
and estates strategy.
Consultancy
0.00
WSP is providing
1990 1995 2000 2005 2010 2015 2020 2025 2030 2035 2040 2045 2050
Year
transportation planning.
www.cibsejournal.com June 2009 CIBSE Journal 47
CIBSEjun09 pp46-48 hospitals.indd 47 28/5/09 17:24:02
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72