SELF-STUDY SERIES CONTINUING EDUCATION TEST • SEPTEMBER 2020


Do your medical device drying processes meet the standards? Circle the one correct answer:


1. Which is the quality standard that addresses instrument air? a. ANSI/AAMI ST79 b. ANSI/AAMI ST 58 c. ANSI/ISA 7-0-01-1996 d. SGNA


2. Instrument air and medical-grade air are the same. a. True b. False


3. To thoroughly dry heat-sensitive devices after manual cleaning, they can be placed in a/an … a. HEPA-filtered drying cabinet b. ETO Sterilizer c. Drawer with a towel wrapped around d. Steam sterilizer


4. When would you use a borescope? a. To visualize internal lumens for retained debris or residual water


b. On a sterile field c. To inspect a malleable retractor d. On a non-lumened endoscope


5. Medical device drying is performed ______? a. In GI before storing an endoscope b. On the decontamination side in SPD before sending a lumened item through the pass- through window


c. On the clean side of the SPD before low- temperature or steam sterilization


d. All of the above


6. According to ANSI/AAMI and other standards, what guidance should be followed for medical device drying? a. The device manufacturers’ IFU b. The high-level disinfector/sterilizer manufactur- ers’ IFU


c. Both a and b d. None of the above


7. Water and moisture create an environment for bacteria to _________. a. Die b. Grow or proliferate c. Move from one place to another d. Easily be removed from a device


8. Wet instrumentation and endoscopes can be the cause of ________. a. Biofilm formation b. Wet packs and corrosion c. Failed low-temperature sterilization loads d. All of the above


9. Medical devices that are susceptible to biofilm formation if not cleaned and dried properly include … a. Endoscopes b. Lumened devices such as a Frasier suction c. Drill bits d. All of the above


10. Who is responsible for establishing a quality management system for medical device moni- toring in the hospital? a. The manufacturers b. The sales rep c. The healthcare facility d. None of the above


The approval number for this lesson is 3M-HPN 200408.


Request for Scoring o I have enclosed the scoring fee of $10 for EACH test taken — Payable to Healthcare Purchasing News. We regret that no refunds can be given. (It is not neccessary to submit multiple tests separately.)


Detach exam and return to: Continuing Education Division Healthcare Purchasing News 2477 Stickney Point Road, Suite 315B Sarasota, FL 34231


PH: 941-927-9345 Fax: 941-927-9588


Please print or type. Return this page only. Name Title


Hospital Name Mailing Address Apt/Suite


City, State, Zip Daytime Phone Email


hpnonline.com • HEALTHCARE PURCHASING NEWS • September 2020 43 Presented by


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62