ADVE
DVERTOR ALRIIAL
TE
TECHNOLOGY IN ACTION Pulse-lessmet eringwith Hydra -Cell ®
advantages of conventional metering pumps with several significant additional benefits.
W
Casella has announced its courses and fofor 2020
webinars schedule fofor
C
asella, a leading world expert in monitoring solutions for noise, air sampling and vibration, has announced its schedule for courses and webinars for 2020.
The company has aligned a series of one-day courses on Air Sampling and Noise Monitoring in the Workplace, hosted at its headquarters in Bedford. Delivered by expert trainers, they provide managers and safety practitioners with guides to best practice, compliance and regulations.
The Introduction to Air Sampling course will run in March, June, September and November, and the Introduction to Noise course will be held in February, May, August and October. Both courses offer attendees a pragmatic guide to best practice, current legislation and the practical use of monitoring equipment, suitable for all levels of experience. In addition, Casella will be running monthly free webinars covering best practices across its core knowledge base and product areas: Introduction to Workplace Noise, Use of SLM s and Noise Dosimeters, Introduction to Personal Dust Monitoring, Setting up Air Sampling Pumps, Introduction to Personal Sampling of Vapours and Gases and Introduction t o Hand Arm Vibration .
Casella Casella +44(0)1234844100
www.casellasolutions.com/uk/en/support/
training.html
Hydra-Cell pumps are internationally recognised for their ‘no pulse; no problem’ accuracy and reliability for metering and dosing applications. The virtually pulse-less, linear flow; lowers acquisition costs, due to their compact size and pulsation dampeners are unnecessary. Maintenance cost due to reducing pipe strain and leaking
connections are also eliminated in most cases. Reduction in noise levels can also be a big advantage.
As with all Hydra-Cell pumps, there are no seals, cups or packing, a design which eliminates leaks, hazards and the expense associated with seals and packing maintenance, lowering the total lifetime cost of ownership.
Hydra-Cell metering solutions unique spring-loaded disc check valves reliably
handle abrasives, liquids with suspended solids and viscous liquids. Solving a lot of problems with chemicals that contain suspended solids or that can form crystals.
As well as exceeding API 675 performance criteria, Hydra-Cell’s metering and dosing pumps are also available to meet ATEX classifications for use in oil & gas applications and chemical & petrochemical pro cessing .
Wa Wanner 01252 816847
www.hydra-cell.eu ATEX Approval for TFX-5000 ultrasonic clamp-on Flowmeter D
ynasonics® TFX-5000 ultrasonic clamp-on flow meters for liquid flow measurement and Heat metering (Heating & Cooling flows) include data logging and alarm history with a time and date stamp and are ideally suited for HVAC, water and wastewater, oil and gas and industrial flow and energy measurement applications.
automotive, waste water, oil an models measuring DN65 and la
hazardous zone approvals.
Whilst this model can be specified for pipe diameters DN12 to DN1200, the approval covers models from DN65 and above and classification is : • II 3 G Ex ec nC ic IIC T4 Gc • II 3 D Ex tc IIIC T100 °C Dc
The TFX-5000 meter uses transit time measurement to determine the flow rate and total volume. When ordered as an energy meter option with the supplied pair of PT1000 RTDs, the TFX-5000 energy meter can calculate heat transfer rate and energy usage clamp on to the outside of the pipe, there i
installation cost while eliminati tap or cut into the pipe, providi meters' clamp on flow sensors
ng considerable benefits in terms of the reduction in total ng the potential for contamination and meter fouling.
The TFX-5000 non-intrusive flow meter replaces the Dynasonics® TFX Ultra - ultrasonic clamp-on meter and is suited to the same applications and more whilst it also includes the following improvements:
• Data logging and real-time clock
• Addition of the adjustable small pipe transducer, only one sensor for small pipes! • Large display with keypa d and improved diagnostic messages • Improved pipe clamp RTDs • AquaCUE® Flow Measurem • Security passcode protection
ent Manager/BEACON® Advanced Metering for energy metering
• English, French, German, Italian and Spanish configuration menus
• SoloCUE® Flow Device Manager configuration software (included free with each model purchased) • The TFX-5000 meter is CE certified. (ATEX approval is on-going and expected for early 2020.)
Be 28 2 8 Bell Flow Syst APRIAPRIL 202 stems 2020 | PROCESSPROCESS & CO CONTRO RO L 01280 817304
sales@bellflowsystems.co.uk CONNECTIN G DNI CONNECTING USTRY.
www.bellflowsystems.co Y.CO M/P OCESS&CONT O /PROCESS&CONTROL
L m
Analytics with remote connectivity
s no requirement to . As the TFX-5000
Badger Meter is happy to announce new hazardous area certification to ATEX/IECEx Zone 2 for the Dynasonics® TFX-5000 transit time ultrasonic flow meter. The certification covers rger, making the solution ideal for flow measurement in d gas and other general industrial applications requiring
anner’s Hydra-Cell Metering and Dosing pumps offer all the
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36