Monitoring & metering
halogens in seafood prior to human consumption, so there is a meaningful risk to life. For these reasons the Environmental
Agency, whose jurisdiction covers England, have followed the lead of slightly more prescient European authorities in making AOX testing mandatory. Although the legislation isn’t yet being rigidly enforced, by summer 2024 all water and wastewater companies seeking to dispose of effluent must demonstrate that they have followed the testing protocols fastidiously.
THE TESTING PROTOCOLS FOR AOX So just what are these tests that waste disposal companies will have to pass to satisfy the
Instrumentation Monthly August 2023
environmental legislation? The name of the molecules being tested for lends a clue: adsorbable organic halogens. “Halogens” covers a group of elements, and it is chlorine that is of most concern in this testing regime. The first step is sample preparation: solid or liquid samples are transformed into an analysis- ready state. Some analytical instruments are limited to either horizontal or vertical sample delivery, meaning only solid or liquid samples respectively are compatible; solid samples require horizontal delivery. To prepare pulp, sludge, sediment or wastewater for AOX analysis, it is acidified, mixed with a nitrate-containing solution and passed through activated carbon columns at a set speed. This prompts the chloride, bromide and iodide ions to adsorb to the surface of the carbon. The carbon is then combusted to release the halogens which are then quantified using microcoulometric titration. Although the dangers of environmental contamination with AOX are clear to all involved, the legislation enforcing testing responsibility on waste companies has been slow to come into effect. When that day comes, however, operations directors can rest easy knowing that technological advancements in AOX testing instrumentation will make the process easier and smoother than ever before. Autosamplers reduce expenditure on technical staff, duplex and triplex columns allow heavier and dirtier samples to be analysed, and flexible sample delivery means both solid and liquid samples can be analysed using the same
equipment. The Multi X2500 Analyser from Analytik Jena is the only one on the market that offers all these features.
Incentivising waste companies to take contaminant testing seriously by making the process more cost-efficient is a crucial step towards better environmental protection. The PlasmaQuant PQMS ICP-MS uses 10-12 L min-1, 50 per cent less argon than other leading ICP-MS systems, saving up to £80,000 over a ten year period. Only through both the carrot of financially appealing options and the stick of effective legislation can the scientific community guard delicate aquatic ecology, and indeed the general population, from chemical contamination.
SciMed
www.scimed.co.uk
55
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80 |
Page 81 |
Page 82