Trusted brand since 1907


We have built up our strong reputation by consistently producing products that are universally recognised for their quality and workmanship.


Disconnectors for photovoltaic applications.


 


500 V DC : 25 A 650 V DC : 18 A / 25 A / 32 A 800 V DC : 12 A / 20 A


Switching program: 2-pole, 6 contacts per circuit (2 x 3 in series) DC-side disconnectors for photovoltaic power supply systems in accordance with IEC 60364-712:2002 1 x 2-pole


Switching program: 2-pole, 8 contacts per circuit (2 x 4 in series) 800 V DC : 18 A / 25 A / 32 A


1 x 2-pole DC-side disconnectors for photovoltaic power supply systems in accordance with IEC 60364-712:2002 2 x Ø 25 2 x Ø 25 KG20B/KG32B 2 x Ø 25 KG41B





 


B


B E


Output + –


H


17


145 124


https://flippingbook.krausnaimer.com/KN_PV_GB/


107


17


KG20B KG32B KG41B


B 100 E —


F 178 H 93 K 190


+ Input – Input


145 124 229 107 250


Wiring diagram


Input +


1T1 1L3


+ Output –


2T3 2L1


– + Input


KG20B/ KG32B


1,25 Nm KG41B 1,80 Nm


KG20B/ KG32B 9


KG41B 10


+ – Output


– Input + N N 1T3 2T1 + Output –


Twist torque for clamping screws


Stripped length


Wiring diagram


Input –


KG20B/ KG32B


1,25 Nm KG41B 1,80 Nm


KG20B/ KG32B 9


KG41B 10


Twist torque for clamping screws


Stripped length


General Data Switch disconnectors in accordance with EN 60947-3, VDE 0660 part 107


Utilization category for photovoltaic applications: DC-PV2 Connecting and disconnecting a PV circuit, where severe overcurrent may occur and where the current can flow in both directions


DC-21B Switching of resistive loads, including moderate overloads


Ambient temperature (enclosed): 50 °C over 24 hours with peaks of up to 55 °C (KG32B from 26 A: 35 °C over 24 hours with peaks of up to 40 °C) Finger-safe terminals in accordance with VDE 0660-514 and BGV A3, protection class IP 20


Maximum conductor cross section (use only copper conductors) single wire or stranded wire flexible wire without / with wire-end ferrules (according to DIN 46228)


KG20B/KG32B: 6 mm² KG41B: 16 mm² KG20B/KG32B: 4 mm² KG41B: 10 mm²


Mounting Plastic enclosure, protection class IP 66 / 67, fully insulated, knock-out entries Handle red, in OFF-position lockable with padlocks, front plate background yellow, cover coupling with interlock


Disconnectors for Photovoltaic Applications 10 Name


KG20B.T206/P3.KL11V KG32B.T206/P3.KL11V KG41B.T206/P3.KL11V


KG20B.T206/P3.KL11V KG32B.T206/P3.KL11V KG41B.T206/P3.KL11V


Art. No. Name


70040674 KG20B.T106/P3.KL11V 70040675 KG32B.T106/P3.KL11V 70040676 KG41B.T106/P3.KL11V


70040674 KG20B.T106/P3.KL11V 70040675 KG32B.T106/P3.KL11V 70040676 KG41B.T106/P3.KL11V


Art. No. Ue 50°C 1 Ie DC-PV2 60°C 2 50°C 1 Ie DC-21B 60°C 2


70046570 650 V DC 18 A 18 A 25 A 22 A 780 V DC 1000 V 70046572 500 V DC 25 A 22 A 25 A 22 A 600 V DC 1000 V 70046573 650 V DC 32 A 32 A 40 A 40 A 780 V DC 1000 V


70046570 800 V DC 12 A 12 A 21 A 21 A 1000 V DC 1000 V 70046572 650 V DC 25 A 22 A 25 A 22 A 780 V DC 1000 V 70046573 800 V DC 20 A 20 A 28 A 28 A 1000 V DC 1000 V


¹ enclosed up to 50 °C over 24 hours with peaks of up to 55 °C | ² enclosed up to 60 °C over 24 hours with peaks of up to 65 °C


Data valid only if the pre-assembled bridges have not been modified. * Valid for ungrounded or midpoint-grounded PV grids, overvoltage category III, pollution degree III


Data valid only if the pre-assembled bridges have not been modified. * Valid for ungrounded or midpoint-grounded PV grids, overvoltage category III, pollution degree III


www.krausnaimer.com www.krausnaimer.com 11


KG20B.T208/P3.KL11V KG32B.T208/P3.KL11V KG41B.T208/P3.KL11V


70040678 KG20B.T108/P3.KL11V 70040679 KG32B.T108/P3.KL11V 70040680 KG41B.T108/P3.KL11V


Max. UL


Ui* PV


General Data Switch disconnectors in accordance with EN 60947-3, VDE 0660 part 107


Utilization category for photovoltaic applications: DC-PV2 Connecting and disconnecting a PV circuit, where severe overcurrent may occur and where the current can flow in both directions


DC-21B Switching of resistive loads, including moderate overloads


Ambient temperature (enclosed): 50 °C over 24 hours with peaks of up to 55 °C Finger-safe terminals in accordance with VDE 0660-514 and BGV A3, protection class IP 20


Maximum conductor cross section (use only copper conductors) single wire or stranded wire flexible wire without / with wire-end ferrules (according to DIN 46228)


KG20B/KG32B: 6 mm² KG41B: 16 mm² KG20B/KG32B: 4 mm² KG41B: 10 mm²


Mounting Plastic enclosure, protection class IP 66 / 67, fully insulated, knock-out entries Handle red, in OFF-position lockable with padlocks, front plate background yellow, cover coupling with interlock


Name Art. No. Name Art. No. Ue 50°C 1 Ie DC-PV2 60°C 2 50°C 1 Ie DC-21B 60°C 2


70046574 800 V DC 18 A 18 A 25 A 20 A 1000 V DC 1000 V 70046575 800 V DC 25 A 20 A 25 A 20 A 1000 V DC 1000 V 70046576 800 V DC 32 A 32 A 40 A 35 A 1000 V DC 1000 V


¹ enclosed up to 50 °C over 24 hours with peaks of up to 55 °C | ² enclosed up to 60 °C over 24 hours with peaks of up to 65 °C


Max. UL


Ui* PV


www.krausnaimer.com/gb_en/catalogues 


● photovoltaic grp ●


ues


isolating switches ● main/emergency off ● changeover switches g roof


the sign of quality


● insulated ● mild & stainless steel ● red painted ● sloping roofls o er swi hes


KRAUSNAIMER.COM 01635 26 26 26 sales-uk@krausnaimer.com


500 V DC / 650 V DC / 800 V DC F


K


F


K


Ø 25


229


250


Ø 25


800 V DC

Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48