Steam turbine basic data | Quick reference tables
Power rating MW Power Model Type rating MW
Shaft speed1 rpm
Dimensions LxWxH m
Weight 1 tonnes ➝
POWER MACHINES, Moscow, Russia.
www.english.power-m.ru (continuation) K-225-12 K-255-162 K-300-170 K-330-240 TK-330-240 K-500-166 K-500-240 K-800-240 K-1200-240
Condensing4 Condensing4 Condensing4 Condensing4 Condensing4
K-1000/60-3000
4-cylinder condensing 4-cylinder condensing 5-cylinder condensing 5-cylinder condensing 5-cylinder condensing
225 255 300 330 330 500 525 800
1200 1062
– – – – – – – – – –
– – – – – – – – – –
2 5 ➝ ➝
10 ➝
20 ➝
50 ➝
100 ➝
200 ➝
500 ➝
1000 ➝
– – – – – – – – – –
Notes: Power rating measured at generator terminals. (1) For district heating applications. (2) Single cylinder condensing. (3) Double cylinder. (4) Triple cylinder. (5) For combined cycle.
SIEMENS ENERGY, Erlangen, Germany
www.siemens-energy.com D-R RLA / RLVA D-R RLH
D-R SST 350 /500/700
D-R 2TA
D-R AVTTW/GTW DR-C
DR-GAF DR-K DR-B
DR-B Tandem DR R/RS
Single stage Single stage Single stage Single stage Single stage Single stage Multi-stage Multi-stage Multi-stage Multi-stage Multi-stage
Notes: Siemens Energy, formerly Dresser-Rand
SIEMENS GAS AND POWER GMBH & CO. KG, Erlangen, Germany
www.siemens-energy.com Purpose built1 SST-200 SST-300 SST-400 SST-6005 SST-800
Various up to 12 500-23000
SST-800/5005 SST-700/900 SST-3000 SST-4000 SST-5000 SST-6000 SST-9000
Back pressure condensing Up to 25 <15000 (2) Back pressure condensing up to 60 <12000 (2) Back pressure condensing up to 60 <8000 (2) Back pressure condensing up to 200 <18000 Back pressure condensing up to 200 3000/3600 Reheat4
BP condensing Reheat4
Non-reheat Reheat4 Reheat4 Reheat
up to 250 30003600 up to 250 3000/3600 90-250
3000/3600
100-500 3000-3600 120-700 3000/3600 300-1200 3000/3600 1000-1900 1500-1800
–
– – –
– – – – – – –
–
– – –
– – – – – – –
0.745 1.865 3.5
3.75 4.5 2.5 3.5
4.85 11
12.5 25
4300-6000 6000
12 000 12 500
225 255 300 330 330 500 525 800
1200 1062
– – – –
10000 9500 8500
15000
– – – – – –
– – – –
–– 8500 6000
– – – – – –
0.745 1.865 3.5
3.75 4.5 2.5 3.5
4.85 11
12.5 25
12 25 60 60
200 200 250 250 250 500 700
1200 1900
Notes:
TGM KANIS TURBINEN, Nuremberg, Germany
www.tgmkanis.com TS
Impulse SBT14
TS1000P TM-Flex TMC TM
TMC-A TM-A G5
Backpressure Impulse Impulse Impulse Impulse Impulse Impulse Impulse Impulse
2 2
1.3 5
17 20 25 55 4
3600-6000 3000-3600 6000 6500
6000-8000 6000-8000 5000-8000 8000 6000
– – – – – – – – –
– – –
– – – – –
2 2
1.3 5
17.5 20.5 25 55 4
44 | | July/August 2023 |
www.modernpowersystems.com
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80 |
Page 81 |
Page 82 |
Page 83 |
Page 84 |
Page 85 |
Page 86 |
Page 87 |
Page 88 |
Page 89 |
Page 90 |
Page 91 |
Page 92 |
Page 93