Gas turbine basic data | Quick reference tables
Model
Gross output1 MW
Gross
Heat rate1 kJ/kWh
efficiency1 %
Shaft speed2
Pressure ratio
Turbine inlet
temp °C
MITSUBISHI HEAVY INDUSTRY, Yokohama, Japan
www.mhps.com (continuation) M501JAC M501J M701G M701F M701J
M701JAC H-25
M701JAC
435 330 334 385 478 574 41
105.8 116.5 448
8182 8552 9110 8592 8511 8295 9949 9421 9400 8182
44
42.1 39.5 41.9 42.3 43.4 36.2 38.2 38.3 44
3600 3600 3000 3000 3000 3000 7280 3600 3000 3000
25 23 21 21 23 25
17.9 18.4 18 25
Exhaust mass flow kg/s
NOx
Exhaust temp °C
emissions3 ppmv
Start up time4
min
Weight5 tonnes
– – – – – – – – – –
764 620 755 748 896
1024 114 293 296 765
645 635 587 630 630 646 569 534 586 663
Notes: All ratings on natural gas fuel, with inlet and exhaust losses, LHV basis; except H series gas turbines where they are given without inlet and exhaust losses. Effective October 2021, Mitsubishi Power will be renamed Mitsubishi Heavy Industry.
MITSUBISHI POWER AERO, Glastonbury, Connecticut, USA
Aero.power.mhi.com FT8 Swiftpac 60 FT8 Swiftpac 30
FT8 Swiftpac 50 DLN FT8 Swiftpac 25 DLN FT8 Mobilepac
FT4000 Swiftpac 140 FT4000 Swiftpac 70 FT8 Swiftpac 60 FT8 Swiftpac 30
FT8 Swiftpac 50 DLN FT8 Swiftpac 25 DLN FT8 Mobilepac
FT4000 Swiftpac 140 FT4000 Swiftpac 70
62 31 51 25 29
141 70 62 31 51 25 31
142 72
9882 9900 9464 9513
10376 8896 8908 9792 9841 9430 9489 9825 8861 8725
36.4 36.4 38
37.9 34.7 40.5 40.4 36.8 36.6 38.2 38
36.7 41.6 41.3
3000 3000 3000 3000 3000 3000 3000 3600 3600 3600 3600 3600 3600 3600
21.3 21.3 19.5 19.5 21.3 37.9 37.9 21.3 21.3 19.5 19.5 21.3 37.9 37.9
– – – – – – – – – –
– – – – – – – – – –
347 317 420 480 560 560 55
175 216 560
– – – – – – – – – – – – – –
184 92
169 84 92
367 183 183 92
169 84 92
367 183
494 494 462 462 496 431 431 491 491 461 461 491 422 422
<=25 <=25 <=39 <=39 <=25 <=25 <=25 <=25 <=25 <=25 <=25 <=25 <=25 <=25
Notes:
NPO SATURN, 152903 Rybinsk, Russia
www.npo-saturn.ru GTE110
110 10466 34.5
1.95 1.95 1.95
– – –
27 27 27
<10 <10 <10 <10 <10 <10 <10 <10 <10 <10 <10 <10 <10 <10
– – – – – – – – – – – – – –
3000
OPRA TURBINES, HENGELO, The Netherlands
www.opraturbines.com OP16-3A OP16-3B OP16-3C
1500/1800* 1500/1800* 1500/1800*
Notes:
SIEMENS ENERGY GLOBAL GMBH & CO. KG, Erlangen, Germany.
www.siemens-energy.com SGT-100 SGT-100 SGT-300 SGT-400C SGT-400C SGT-400C SGT-600
5.1 5.4 7.9
SGT-700 33MW SGT-700 35MW SGT-750
Notes for table headings:
10.5 12.9 14.3 24.5 32.8 35.2 39.8
11945 11913 11704 10173 10354 10103 10720 9675 9466 8922
30.1 30.2 30.8 35.4 34.8 35.6 33.6 37.2 38
40.3
17384 17384 14045 11500 9500 9500 7700 6500 6500 6100
14
15.3 13.7 16
16.9 18.5 14
18.7 20.4 24.3
– – – – – – – – – –
14.7
1210
362
517
–
25
370
6.7 6.7 6.7
– – –
8.7 8.7 8.7
570 570 570
–
<15 –
1 1 1
1.6 1.6 1.8
19.5 21
30.2 34.2 40
44.5 81.3 95
98.7 115.4
544 549 534 510 555 529 543 533 531 468
– – – – – – – – – –
(1) Simple cycle at generator terminals, ISO conditions. Heat rate LHV, kJ/kWh unless otherwise stated. (2) Power shaft. (3) At 15% O2 dry, ppmv. (4) From cold (5) Thermal block
34.9 34.9 59.4 83.8 83.8 83.8 152 163 170 175
38 | July/August 2022 |
www.modernpowersystems.com
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80 |
Page 81 |
Page 82 |
Page 83 |
Page 84 |
Page 85 |
Page 86 |
Page 87 |
Page 88 |
Page 89 |
Page 90 |
Page 91 |
Page 92 |
Page 93