SAFETY & SECURITY Going beyond Gateway 2
Chris Hall of Siderise looks at the new design quality regime under the Building Safety Act, and the Gateway 2 approval for higher-risk buildings in particular, discussing what architects need to know on the documentation requirements
Reports from the Building Safety Regulator suggest that so far, applications have frequently lacked the level of detail and documentation necessary to progress through Gateway 2 smoothly, leading to project delays
O
ne of the most significant changes brought in by the Building Safety Act (BSA) is the new building control regime and approval ‘Gateways’ for higher risk buildings (HRBs) – in particular Gateway 2. Here, a full application is submitted to the Building Safety Regulator (BSR) outlining how compliance with the functional requirements of the Building Regulations will be met, and construction cannot begin until it is approved. For architects, this means that plans must be prepared with an appropriate amount of detail, particularly around key elements such as fire safety. However, reports from the BSR suggest that so far applications have frequently lacked the level of detail and documentation necessary to progress through smoothly, leading to project delays. To help overcome this, there is a clear need for construction product manufacturers – especially those producing life safety-critical products – to provide support beyond the basics of accurate product information.
Fundamental information Accurate and substantiated product information is essential for safe designs, regardless of the building type or use. Therefore, as standard practice, manufacturers must ensure architects have access to clear, accurate and up-to-date
WWW.ARCHITECTSDATAFILE.CO.UK
product information that is not ambiguous. Any performance claims should be backed up by testing carried out to the standards stipulated by the applicable compliance guidance or the regulations as a minimum. These results should be verified by accredited third-party certification bodies wherever possible for greater assurance. This data should also be captured within usable BIM models which have been authored to industry standards such as the NBS BIM Object Standard. However, a common misunderstanding is that Gateway 2 is simply an assessment of the building design. The BSR states that plans need “to outline exactly how compliance with the functional requirements of the Building Regulations is going to be met – and that they do not rely on unrealistic management expectations.” This means that there needs to be detailed justifications of why certain products or approaches are being used on a specific project and how they contribute to compliance. For this to happen, contractors and specialists must not only be brought into the design process at a much earlier stage than what had become the norm, but manufacturers must be ready to share their expertise to ensure products are used correctly to support compliance and long- term safety of the building.
Application support
Manufacturers are often considered specialists, and are seeing an increasing trend of being asked to support designers in preparing key details or providing the right training and education at this crucial stage. This can include project-specific advice and guidance ranging from product selection and calculations, to arranging bespoke testing of specific elements. For project teams, working with manufacturers earlier on in the construction process can also help to limit the risk of changes to specifications, as the products will not only be specified correctly for
ADF OCTOBER 2024
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76