MODERN METHODS OF CONSTRUCTION
and standards meaning the rates are not directly comparable. However, this rate is significantly more stringent, requiring close attention to details.
Above and beyond these targets, the Passivhaus standard also requires that buildings be independently assessed post completion to ensure they meet the performance targets not only on paper, but also in practice. Only once this has been confirmed will the building achieve certification. This essential step has helped ensure that there is little if any performance gap in Passivhaus properties.
Passivhaus approach In addition to these targets, the Passivhaus standard sets out a clearly defined process for delivering them. Properties need to be highly insulated with careful attention paid to all details to effectively deliver a ‘thermal bridge-free’ construction. Air leakage rates through the fabric should also be effectively limited using a range of measures – including specialist triple-glazed windows. A Mechanical Ventilation Heat Recovery (MVHR) system is used to ensure a good level of ventilation is maintained within the property. These systems use a heat exchanger to take the heat from stale outgoing air to warm fresh incoming air, further limiting overall heating demand.
Offsite solutions
The high performance criteria of the Passivhaus standard raise obvious questions on how this can be accurately and affordably delivered at scale in Scotland. One solution already used on a large number of UK Passivhaus projects is the adoption of structural insulated panels (SIPs).
SIPs are fabricated by bonding two sheets of particle board or oriented strand board (OSB) on either side of a rigid insulation core. This creates a highly insulated panel which can be used to create both pitched roofs and walls, whose thermal performance can be easily raised further with an additional insulation liner. The panel’s arrangements, dimensions and interactions are designed in CAD. They are then pre-cut at production facilities using CNC cutting machinery. This helps to ensure the cut panels precisely match the designs including openings for windows and doors. This supports accurate detailing to eliminate thermal bridges and limit air leakage around these junctions.
WWW.ARCHITECTSDATAFILE.CO.UK
The Passivhaus Trust’s recommendations call for the Scottish standard to be based on the full Passivhaus, including local weather data
Some SIPs also feature a cassette joint which slots into a routed channel between the panels, ensuring excellent insulation continuity across the envelope and further limiting air leakage. Once an airtight membrane is fitted internally and tape is applied to junctions, the air leakage rate can be reduced to the requirements for Passivhaus.
In addition to simplifying installation processes onsite, the offsite production process for SIPs also helps to provide scalable scheduling benefits. The factory cutting process allows identical panel kits to be produced for multiple units without the errors and inaccuracies common with traditional onsite processes. Production timescales can be easily predicted, allowing for accurate scheduling and improved site logistics.
The shells of individual housing units can typically be erected in around two weeks by a small team of site operatives with lightweight lifting machinery. Once a breather membrane is applied and windows and doors fitted, work can then begin on internal fit-out, further speeding up the construction process.
SIPs can also support a wide range of facades including timber cladding, brick slips and renders to meet project requirements.
Looking ahead In March, the Passivhaus Trust published its recommendations for the Scottish standard. These called for the standard to be based on the full Passivhaus, adapted into a Scottish- owned version including local weather data. It also suggested a phased transition, allowing time for upskilling, with buildings being accepted as “deemed to satisfy” the new standards by January 2025. Use of established technologies, such as SIPs, can support this transition – helping project teams to meet these ambitious timelines.
Jonathan Ducker is head of regulatory affairs at Kingspan Insulation
ADF MAY 2024
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80 |
Page 81 |
Page 82 |
Page 83 |
Page 84