INSULATION


Steel faced PIR core insulated panels can readily achieve the required U-values with minimal thickness


Measuring compliance


The National Calculation Methodology (NCM) remains the means by which compliance must be demonstrated, with an updated version of the Simplified Building Energy Model (SBEM) available to calculate aspects such as the Target and Building Emission rates (TER/BER) as well as the Target and Building Primary Energy Rates (TPER/BPER).


The introduction of the Primary Energy rate as an additional metric by which performance is measured was one of the most notable changes. The metric applies a fuel factor adjustment to the energy used, accounting for upstream activities to prepare the fuel for use, this includes steps such as extracting, refining and transporting fossil fuels. The primary energy demand for a building also factors in the fabric performance of the building and the efficiency of the heating technology used. Carbon emissions were also retained, allowing some consistency in the benchmarking process – both metrics must be met for a building to comply. Interestingly, amendments were introduced in February 2023 to remove the Primary Energy factor as a performance standard where district heat networks or community heating is being used. Buildings with a useable floor area of 500 m2 or more must be subjected to pressure testing to assess air permeability. As the building envelope becomes more efficient, thermal bridging becomes a more significant factor, so ADL2 (England) requires accurate calculations of the psi values at junctions and penetrations, with a 50% penalty if assumed psi values are used instead of project specific calculations. To support this approach accredited details were removed.


Complying with Part L


Steel faced PIR core insulated panels readily achieve the required U-values with minimal thickness. For example, the minimum U-value for a flat roof is 0.18 W/m2


.K, 0.16 W/m².K for pitched – a


typical trapezoidal insulated panel can achieve 0.16 W/m2.K with just 120 mm thickness. The single unit panels ensure insulation continuity, and manufacturers can often provide detailed psi values to use in building energy modelling, helping to avoid penalties.


Chris Pateman is general secretary at EPIC WWW.ARCHITECTSDATAFILE.CO.UK ADF JULY/AUGUST 2023


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88  |  Page 89  |  Page 90  |  Page 91  |  Page 92