COAGULATION
combinations, allowing for a wider range of tests with greater precision. A standout benefit, according to the team at Centre Hospitalier Universitaire à Limoges: “What impressed us the most was the throughput and turnaround time (TAT) of the sthemO 301. The wider the range of tests, the greater the difference with the STA R Max. As an example, we evaluated this difference at 40 minutes on a mixed panel of tests (PT/APTT/FIB) for 100 samples. On our STA R Max, it takes 1 hour 45 minutes to complete this while it only takes 1 hour 5 minutes with the sthemO 301. “We were also able to evaluate the
time to results for a tube with PT/APTT/ FIB tests loaded on the dedicated STAT sample area. It took around 10 minutes to get the results on STA R Max and only eight minutes on sthemO 301.”
Cuvettes and beads n Ergonomic cuvette packaging for easy loading
n ‘Place and twist’ bead dispenser for safe and simple loading
n Test management optimised by the analyser, increasing throughput of all test combinations.
sthemE: maximising quality for peace of mind
The sthemE range of eSolutions further maximises laboratory productivity, while empowering scientists to pilot their Stago coagulation solution from any computer in their laboratory, including complex organisations with multiple sites and LIS.
sthemE Manager Stago’s data manager, delivers true cross-site connectivity, allowing biomedical scientists to review patient results from a centralised database at any location, enhancing patient and quality management. Meanwhile, results auto-validation and Stago patented
100 100 80 80 Good 60 60 53 40 40 20 20 0 0 2018 2019 2020 2021 2022 2023
Increasing Net Promotor Score seen in customer satisfaction surveys undertaken between 2018 and 2023 (NPS grading as per Bain & Company).
WWW.PATHOLOGYINPRACTICE.COM SEPTEMBER 2024 44 57 74 72 82 Exceptional
Continuous sample loading and unloading enables users to respond quickly to workload fluctuations. There is a dedicated loading position for urgent samples, as shown above.
expert rules remove the burden from less experienced staff by offering analytical guidance and support needed to make the right decisions. Several CE-marked Stago coagulation algorithms are already available.2,3
These algorithms further
demonstrate Stago’s commitment to enabling laboratories to deliver the best possible patient care, even when facing workforce challenges.
sthemE Qualiris An intuitive, comprehensive ISO-17043 accredited EQA program dedicated to haemostasis and thrombosis. Complementing the NEQAS EQA scheme, the program provides detailed reports that allow scientists to confidently master the evaluation of their results and comparison with their peers – ensuring
conformity, high quality and exceptional performance level.
sthemE Expert QC A robust IQC peer-comparison tool that allows scientists to effortlessly assess the quality of their entire assay repertoire. Data are automatically uploaded through sthemE Connect, allowing users to quickly identify potentially abnormal trends, and ensure systems are always at the peak quality performance level. Globally, there are more than 4000 instruments subscribed, meaning the peer groups are large and statistically robust.
sthemE Connect This provides remote troubleshooting, enabling Stago’s skilled and experienced teams to assist scientists and support them when they need it most, while helping to boost customer satisfaction and NPS scores. sthemE Connect also enables the automatic and secure transmission of sthemE Expert QC data and CPRR reports to Stago servers.
sthemE Accreditation Part of sthemE Manager, this service simplifies ISO15189:2022 compliance and UKAS assessments. Stago made the method verification and performance monitoring even easier with a comprehensive ‘accreditation toolkit’ and ‘360° Quality’ solution. As Lenka Mercer, senior biomedical scientist in coagulation at the Royal Sussex County Hospital, explains, sthemE Accreditation is “Far more than just innovative software,
17
NPS
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56