Production • Processing • Handling
Steam traps manufactured from corrosion-resistant stainless steel
Steam traps stop mechanical trap failure and reduce condensate return pressure by 15 per cent at refinery.
K
eeping on top of the constant challenge of repairing and replacing thousands of mechanical steam traps is no longer a problem at KNPC’s Shauiba Refinery in Kuwait following the
conversion of 1750 mechanical traps to Termal Energy International’s GEM Venturi Orifice design. In addition, KNPC, a subsidiary of the Kuwait Petroleum Association, has seen the HP hot condensate header pressure drop from highs of 175psig to just 90psig. Commissioned in 1968, Shuaiba Refinery, located some 50km south of Kuwait City, occupies an area of 1 332 000sqm producing approximately 30 types of light, medium and heavy petroleum products. Tese consist of mainly gas, ordinary naphtha, various kinds of fuels such as high-octane gasoline, kerosene and ATK as well as automotive diesel, marine diesel, fuel oil and sulphur, which is a by-product of the industrial process. As is the case in oil refineries worldwide, steam is the primary means of transporting energy from the numerous boilers and steam generators to the point of use and is used throughout the oil refinery for applications ranging from trace heating systems designed to keep the product at the correct viscosity to large reboilers consuming many tonnes of steam per hour.
As the steam gives up its useful heat it condenses
to water. Te steam trap’s function is to remove this water and air from the steam pipework. At Shuaiba Refinery the mechanical steam traps were failing at a rate of in excess of 10 per cent per annum. Steam traps can fail in either the open position, resulting in the trap passing live steam, or closed which prevents the discharge of condensate from the system. When Termal Energy International was
first approached by the Shuaiba Refinery, failed mechanical traps had caused the condensate return pressure to rise to 175psig, preventing the 150psig steam stem from being able to discharge. During a recent unplanned boiler outage, the refinery was able to run on just two boilers which prior to the installation of the GEM Venturi Orifice steam traps would have resulted in a loss of steam pressure
24
www.engineerlive.com
to the refinery’s extremities and impacted on production. “Use of GEM traps has resulted in an 85psig l
reduction in the HP hot condensate header pressure as well as steam savings from the reduction in steam loss,” said Habib M Atesh, Engineering & Maintenance Manager at Shuaiba Refinery. “In addition GEM traps are superior as only the strainers require maintenance”.
Instead of utilising a valve mechanism to close off steam for maximum energy and water conservation, the highly efficient GEM steam traps use the venturi orifice design to effectively drain condensate from the steam system.
As the GEM steam traps have no moving parts to wedge open or fail, it provides the ultimate in reliability necessitating only minimal maintenance and requiring no spares, testing or monitoring equipment. Available in a wide range of sizes for a full cross
section of applications, the hardwearing GEM steam traps are manufactured from corrosion resistant stainless steel and are guaranteed for 10 years, obviating the need for repair or replacement. ●
Thermal Energy International Inc is based in Bristol, UK.
www.gemtrap.com
Fig. 1. KNPC’s Shauiba Refinery in Kuwait.
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56