Chemical Equipment Update
❒ Diaphragm (or bellows meter): These are common in many people’s home as their domestic gas meters. When the gas flows through it alternately fills and empties bellows causing levers to crank a shaft providing an output. Very useful for wide-ranging gas totalisation.
❒ Oval Gear: Quite similar to the spur gear where two oval gears mesh together and sweep the chamber. The volume displaced is much larger than the round gear. Fairly low cost and some designs available in plastic.
❒ Nutating Disc: This meter is the hardest to understand but is effective. The rotor is a circular disc attached to a ball. The shaft on the ball is inclined. As the disc rotates in a spherically sided chamber the disc and therefore the shaft wobble creating an output.
❒ Helical Screw: Possibly the most accurate PD: meter two intersecting cylindrical bores are fitted with 2 interlocking helical screws. As the fluid passes through they rotate. On standard applications the author has observed differences of just ±0.37 per cent of reading over 50:1 turndown over annual recalibrations over 10 years – quite an achievement. Also common nowadays fitted on petrol pumps.
❒ Slide Vane: Historically the most accurate of PD meters with the rotating element having a number of moving blades that rotate about a fixed cam. Linearities have been claimed of ±0.02 per cent.
❒ Others: If we go back to Felix Wankel’s seminal work on rotary machines we see that there are as many designs for PD meters as there are pumps. He explored in a rational way the various shapes of rotor and chamber. While the majority don’t see the light of day in the marketplace this brief essay illustrates the variety in general use, and this is without discussing the Roots meter, wet gas meter and multi rotor designs.
Fig. 3. Rotary Piston meter, high pressure stainless steel versions, 700:1 turndown on water.
Photo courtesy Litre Meter.
flows, as well as high pressures and for food applications. A good all-rounder.
❒ Spur gear: The fluid rotates two gears and is forced around the outside of the gears and the inside of the chamber. Depending on the location of the sensor these can yield very high pulses per litre values useful in batching and fast acting processes.
Two decades ago the PD meter was considered to be old technology and likely to be overtaken by more modern electromagnetic and ultrasonic devices. Nowadays the PD meter still represents good value and can provide excellent measurement in a wide variety of duties. ❒
Enter 18 or ✔ at
www.engineerlive.com/ece
Charles Wemyss is Engineering Director, Litre Meter Ltd, North Marston, Buckingham, UK.
www.litremaster.com
Fig. 4. Rotary Piston flowmeter, measurement principle. The oscillation of the rotor creates fixed-volume discrete parcels of fluid.
18
www.engineerlive.com
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44