PHAM NEWS | NOVEMBER 2025 PHAM NEWS | NOVEMBER 2025


HeatPumpsHeatPumps Why sizing matters Why sizing matters


Over or undersizing a heat pump can result in a loss of performance and effi ciencies. Darran Smith from Alpha explains why heat loss calculations and fl ow temperatures are key to a successful installation.


Over or undersizing a heat pump can result in a loss of performance and effi ciencies. Darran Smith from Alpha explains why heat loss calculations and fl ow temperatures are key to a successful installation.


becoming a core business for many becoming a core business for many


A


s the UK’s low- carbon heating market continues to grow, air source heat pumps are steadily


s the UK’s low- carbon heating market continues to grow, air source heat pumps are steadily


installers. While many will be used installers. While many will be used


to replace familiar gas boilers, the to replace familiar gas boilers, the


design process is very diff erent design process is very diff erent


and sizing the unit correctly is and sizing the unit correctly is


critical. Where a boiler might critical. Where


forgive an educated guess, a heat forgive an educated guess, a heat


boiler might


pump will not. Correct sizing isn’t pump will not. Correct sizing isn’t


just good practice – it’s essential just good pr ctice – it’s essential


for performance, effi ciency, and for p rformance, effi ciency, and


homeowner satisfaction. homeowner satisfaction.


installer experience and general sizing rules were often enough to achieve a comfortable, working system. Boilers could be slightly oversized without serious consequence, thanks to modulation and the responsive nature of gas combustion. Heat pumps are far less tolerant. An undersized unit may struggle


When installing gas boilers, When installing gas boilers,


installer experience and general sizing rules were often enough to achieve a comfortable, working system. Boilers could be slightly oversized without serious consequence, thanks to modulation and the responsive nature of gas combustion. Heat pumps are far less tolerant. An undersized unit may struggle


Darran Smith Technical manager at Alpha


Darran Smith Technical manager at Alpha


to reach target temperatures to reach target temperatures


an oversized one will short


during the coldest periods, while during the coldest periods,- whicycle an oversized one will short-cycle increased wear and energy costs. With electricity typically costing three to four times more per


increased wear and energy costs. With electricity typically costing three to four times more per


kilowatt-hour than gas, mistakes kilow tt-hour than gas, mistakes


are magnifi ed. Homeowners are magnifi ed. Homeowners


signifi cant investment. signifi cant investment.


really don’t want to pay more for really don’t want to pay more for


what would’ve already been a what would’ve already been a


At their best, heat pumps a At their best, heat pumps four units of heat for every unit of electricity used. However, that performance depends entirely on accurate system design, appropriate operating temperatures, and correct sizing from the beginning.


re capable of delivering up to are capable of delivering up to


four units of heat for ev ry unit of electricity used. However, that performance depends entirely on accurate system design, appropriate operating temperatures, and correct sizing from the beginning.


Heat loss calculations Heat loss calculations


A comprehensive heat loss A comprehensive heat loss


calculation is mandatory for calculation is mandatory for


a successful installation. This a successful installation. This


escapes through the building escapes through the building


nd run ineffi ciently, resulting in and run ineffi ciently, resulting in


aintain comfort levels. maintain comfort levels.


appropriate emitter design, ensuring that radiators or


This data also guides


appropriate emitter design, ensuring that radiators or


Our range offers


Low Carbon Heating Solutions Ground-source


Air-source


Water-source Biomass


DISCOVER THE FUTURE OF HEATING BioWIN -


AeroWIN - Heat Pumps


We recommend BWT


chemical-free chemical-free


heating water for all our systems


heating water for all our systems


Tel: 01225 892211 / Email: info@windhager.co.uk / Website: www.windhager.co.uk Tel: 01225 892211 / Email: info@windhager.co.uk / Website: www.windhager.co.uk


We recommend BWT


BioWIN - Wood Pellet Boilers Wood Pellet Boilers


AeroWIN - Heat Pumps


process assesses how much heat process assesses how much heat


fabric to determine exactly how fabric to determine exactly how


much energy must be replaced to much energy must be replaced to This data also guides


underfl oor heating circuits are correctly sized for each room’s heat demand. New-build properties generally make this straightforward, as Building Control data often provides the necessary fi gures. Existing homes can present challenges due to unknown insulation levels, air leakage, or thermal bridging. A detailed on-site survey remains the best way to capture reliable information. Digital tools and MCS-


underfl oor heating circuits are correctly sized for each room’s heat demand. New-build properties generally make this straightforward, as Building Control data often provides the necessary fi gures. Existing homes can present challenges due to unknown insulation levels, air leakage, or thermal bridging. A detailed on-site survey remains the best way to capture reliable information. Digital tools and MCS-


compliant software make heat compliant software make heat


loss calculations easier, but loss calculations easier, but


they are only as accurate as the they are only as accurate as th


decimal point can completely decimal point can completely


to avoid errors. to avoid errors.


data entered. A single misplaced data entered. A single misplaced


distort results. Installers should distort results. Installers should


take time to understand how their take time to understand how their


chosen software interprets inputs chosen software interprets inputs


MCS-compliant installations mMCS-compliant installations BS EN must meet the requirements of room- 12831, which calls for a ensures that the system delivers the right output in every space and avoids the ineffi ciencies and avoids the ineffi ciencies sizing.


ust meet the requirements of 12831, which calls for a


BS ENby-room assessment. This room-by-room assessment. This


ensures that the system deliv rs the right output in every space


ssociated with over- or under- associated with over- or under-


sizing.Hot water demand must also Hot water demand must also


be considered, as the appropriate cylinder size and recovery rate depend heavily on occupancy patterns.


be considered, as the appropriate cylinder size and recovery rate depend heavily on occupancy patterns.


25 25


Local conditions Heat pumps are sized to maintain a set indoor temperature based on the minimum design temperature for the location. This regional diff erence is signifi cant. While -3°C may be suitable for much of southern England, areas in Scotland and northern England can regularly experience -5°C or below. Using local design temperatures from CIBSE weather data helps avoid undersized installations and ensures reliable operation during peak conditions. System effi ciency also depends heavily on fl ow temperature. Most heavily on fl ow temperature. Most at lower fl ow temperatures, at 45°C or below. This can be even cooler when underfl oor heating is used. Correctly sized pipework and emitters are key to maintaining these lower temperatures. Taking the time to carry out acTaking the time to carry out ssumptions, and understand the


Local conditions Heat pumps are sized to maintain a set indoor temperature based on the minimum design temperature for the location. This regional diff erence is signifi cant. While -3°C may be suitable for much of southern England, areas in Scotland and northern England can regularly experience -5°C or below. Using local design temperatures from CIBSE weather data helps avoid undersized installations and ensures reliable operation during peak conditions. System effi ciency also depends


t pump systems perform best heat pump systems perform best


at lower fl ow temper tures, at 45°C or below. This can be even cooler when underfl oor heating is used. Correctly sized p pework and emitters are key to maintaining these lower temperatures.


curate calculations, verify accurate calculations, verify property’s true heat demand is time well spent. It’s also key for the greater uptake of heat pumps, which already face scepticism over how well they perform. In doing the hard work upfront to help realise their eff ectiveness, we can help shift perception into a more positive light.


assumptions, and understand the property’s true heat demand is time well spent. It’s also key for the greater uptake of heat pumps, which already face scepticism over how well they perform. In doing the hard work upfront to help realise their eff ectiveness, we can help shift perception into a more positive light.


◼ phamnews.co.uk/1125/37 ◼ phamnews.co.uk/1125/37


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44