Kitchen Safety
there have been several instances of faulty grills on almost new cookers causing death and injury. Oversized pans and interference with burners using foil, associated with particular styles of cooking, have also caused CO problems.
Smart systems Mains CO alarms are easily installed alongside hard-wired smoke and heat alarms. But together they can offer extra safety features as well. Notably, Kidde’s 4MCO and 4MDCO hard-wired CO alarms can not only be interlinked with each other but also with the company’s latest Firex range of hard-wired smoke and heat alarms, using the unique ‘Smart Interconnect’ feature. Here, all the interconnected alarms can act as sounders to alert of either risk, forming comprehensive systems. Crucially, the alarms have different, distinct
Kidde mains CO alarms can interlink with smoke/heat alarms to warn of fire as well.
Heat alarms detect increases in the ambient
temperature of the air, rather than smoke from a fire. They are triggered if the temperature rises above a predetermined threshold. They respond more slowly to fires than smoke alarms but are less likely to give nuisance alarms and require less maintenance. They must always be interlinked with smoke alarms elsewhere in the property so that all the alarms sound as soon as one is triggered. The Code recommends them for garages as
well as kitchens and utility rooms, and positioned so that no point in the room is more than 5.3m from one. As with smoke alarms, heat alarms should preferably be ceiling-mounted at least 300mm (horizontally) from walls or light fittings, away from heaters and vents, but accessible for maintenance.
Fire and CO alarms together We believe that there is also a strong case to promote carbon monoxide alarms alongside smoke and heat alarms and we share the Scottish Government’s view (in a recent consultation) that: “it makes practical sense to combine installation programmes for fire and smoke alarms and carbon monoxide alarms together”. This time, the standard is BS EN 50292:2013, which recommends that, ideally, a CO alarm should be installed in every room containing a fuel burning appliance, including cooking, and elsewhere to give warning, such as bedrooms. Building Regulations requiring CO alarms do
apply to some combustion heating appliances but they exclude appliances solely for cooking, unlike the standard. Of course, kitchen and utility rooms with boilers should have CO alarms but combustion cooking appliances are important as well. For example, annual gas safety checks may
exclude the tenant’s cooker where it is not the landlord’s property, posing an increasing risk, and
www.ewnews.co.uk Heat alarms linked to smoke alarms are key to housing safety. November 2017 electrical wholesaler | 21
alarm sounder patterns for carbon monoxide and fire, as required by BS 5839-6. They can automatically alert occupants of the specific hazard allowing them to respond quickly, making the right choice from the very different alternative actions for either fire or carbon monoxide.
Sometimes fitting a battery-only CO alarm may be simpler and, of course, quality is key to long term, problem-free performance, addressed by the latest generation of alarms. Manufacturers that produce their own CO cells rather than buying them in can apply tighter quality controls, giving the confidence that the CO sensor will work effectively throughout the alarm’s design life. Here, Kidde’s 10LLCO is the only range of 10- year guaranteed alarms with CO sensors – the key component – actually tested throughout a 10-year period or longer. CO alarms can be wall or ceiling mounted and BS EN 50292:2013 provides detailed recommendations for positioning, generally between 1m and 3m from the combustion
Kitchen heat alarms are needed in addition to hall smoke alarms.
appliance. Care should be taken in kitchens, avoiding fitting: in enclosed spaces (such as cupboards); directly above a sink, next to a door, window, extractor fan or air vent; or in the immediate vicinity of a cooking appliance. As a straightforward, low cost early warning, wider installation of smoke, heat and CO alarms should be considered as an essential first step for fire safety, whatever other measures are taken, to make all housing safer.
www.kiddesafetyeurope.co.uk Without doubt, heat alarms are essential
in all kitchens and utility rooms. Stockists should now consider promoting them to their customers for use in housing of all types –new or old.
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64