INDUSTRY UPDATE


Smart sensor for condition monitoring


Cooling curve monitoring in glass annealing lehrs


T


hermalert 4.0 spot pyrometers from Fluke Process Instruments enable precise monitoring of critical glass manufacturing processes such as annealing of glass bottles and containers. The noncontact infrared sensors measure product as well as belt temperatures. That way, operators can ensure that the lehr is set correctly for products with different glass thicknesses and sizes, and that the transportation belt is heated correctly. The latter is especially important for glass containers with a thick bottom, to prevent uneven cooling and breakage. Continuous monitoring helps operators improve quality and uniformity and reduce reject rates. It also supports troubleshooting by detecting faulty burners under the transportation belt. The annealing process is designed to remove residual


stress in formed containers. Obtaining the correct temperature and cooling curve is essential to achieve the required strength in the finished product.


Fluke Process Instruments  marcom2.emea@ flukeprocessinstruments.de


www.flukeprocessinstruments.com


should always be under control. The permanent measurement of temperature and humidity in the switch cabinet is an important element in preventing condensation, which leads to corrosion and thus failure of components. STEGO's CSS 014 smart sensor combines a sensor, interface and transmitter all in one compact device. It measures ambient temperatures with high sensitivity within a range of -40 to +60°C while keeping a close eye on the relative humidity range from 0 to 100% RH.


C The CSS 014 transmits


the data it acquires as a standardised analogue 4-20 mA signal. This signal users can further process and convert the measured values within a control or monitoring unit, e.g. a PLC. Due to high measuring accuracy and signal strength connection wires with a maximum length of 30m can be used.


STEGO  01372 747250  www.stego.de


ondition Monitoring is all about paying attention to detail. The key parameters within the switch cabinet


Emparro ACCUcontrol


Keeping machines running Few things are as irritating (or expensive) as unplanned downtimes of plants and machines. The Murrelektronik UPS-module Emparro ACCUcontrol extends the powerful Emparro power supply system and keeps machines running by switching smoothly to battery operation in the event of a mains power failure. The investment in a UPS system frequently pays for itself the first time downtime is avoided.


Predictive maintenance – Be alerted before the failure Emparro ACCUcontrol continuously monitors the internal resistance of the connected batteries. When a limit is exceeded, the device sends a warning signal over a signaling contact. The battery replacement can then be planned for the next scheduled service. This predictive information prevents unplanned downtimes and avoids the need to arrange for service visits at short notice.


Murrelektronik UK  0161 728 3133  sales@murrelektronik.co.uk


Two Birds with One Stone Inductive Position Measurement - ready for Industry 4.0 T


he new PMI F90 inductive positioning system from Pepperl+Fuchs can precisely detect the absolute


position of one actuator as well as the distance between two. Thanks to IO-Link technology, the system has comprehensive communication functionality and is equipped for I4.0 applications. Patented multi-coil technology guarantees maximum measurement accuracy.


Driving Innovation to Your Door… “I


didn’t know you did that!” It's something Pepperl+Fuchs often hear. Yet Pepperl+Fuchs are committed to innovation and bringing new ideas to their clients From November 2018 Pepperl+Fuchs are taking to the


road with their Mobile Exhibition Bus to showcase their latest innovations.


Don’t miss the opportunity to be inspired by their


latest technologies and attend their tailor-made training courses to suit customer requirements. Seating between four and six people the vehicle transforms into a portable classroom.


With a full set of exhibition panels inside, the custom- built mobile exhibition vehicle offers visitors the same experience as stepping on to a stand at a show but without the inconvenience of travelling. "Fully wired and working sensors allow us to quickly


communicate the features of a product often saving considerable time for our customers compared to a


38 November 2018 | Automation


conventional sales call," - Paul Cusack, UK Sales Manager with Pepperl+Fuchs. Sensor surgery is open. Their team of sensor experts and industry specialist will be on-board and ready to discuss your sensing and positioning challenges. "While online product evaluation and selection process


have come a long way, there is still much to be said for real life "browsing" when it comes to broadening your knowledge of new products and technologies available." Says Mark Timmins, Marketing Manager. "Our products are not "virtual" they are designed to sense and interact with the real world and being able to touch and test them is often distinctly beneficial for our customers."


Jump aboard and connect to the innovation.


Pepperl+Fuchs  0161 633 6431  www.pepperl-fuchs.com


automationmagazine.co.uk


The new PMI F90 inductive positioning system works with a unique, patented multi-coil system. The absolute position of the actuator is precisely detected from the measuring signals of a single coil. In addition to sending the analog position signal, switch points can also be defined. The sensor can detect two actuators as well as the distance between them, meaning that dynamic positioning tasks can be completed with the smallest amount of measuring technology.


Pepperl+Fuchs  0161 633 6431  www.pepperl-fuchs.com


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66