PUMPS, VALVES & ACTUATORS


AERATION SOLUTION TO TANK WITHIN TANK CHALLENGE


Fifteen years on from its first wastewater project with a popular provider of freshly prepared food, FLI CAP Technology has completed its latest bespoke installation for the brand, using Landia’s AirJet system


T


o meet the ever-increasing demand at the food producer, FLI Cap Technology were tasked partly with providing a new CIRIA-compliant (Construction Industry Research and Information Association) above-ground treatment tank that would ensure safe secondary containment of hazardous liquids. Creating a second-skin tank around the outside of a vessel presents access challenges as FLI CAP Technology's Divisional Director Chris Woods, explained: “The best solution for aerating our customer’s tank was with submersible mixers, but we were keen to avoid the health and safety issues involved with working at height when removing the equipment for maintenance.


“Based on its quality,


efficiency and longevity we specified Landia's AirJet system which includes their proven chopper pump. We were able


to install this 11kW system at ground level for the required tank-within-tank concept, with Landia assisting us in creating an elevated aspiration system so that the Venturi nozzles would create sufficient mixing for the glass- lined steel tank (inner diameter 6m, height 9.4m; with an outer bund of 7.9m diameter and a height of 7.9m)”.


A simple aeration system that can be easily installed in most tank types, often without emptying the vessel first, the Landia AirJet is an ejector aerator, typically used for the


aeration of wastewater or sludge, comprehensively mixing and aerating the whole tank to eliminate unpleasant odours. AirJet is also suitable for supplementary aeration at peak loads, and in connection with cleaning or flushing of equalization tanks. Woods added: “As our customer expanded to create a fourth production line for a 35% increase in capacity, we needed to find an innovative design that greatly reduces residual risks with the project. Ensuring that our customer met CIRIA’s important C736 requirement was paramount, but keeping moving parts at ground level also makes maintenance significantly easier for them, greatly reducing health & safety issues, hassle, and costs.” In addition to the bunded balance tank and aeration system, FLI CAP Technology’s complete turnkey effluent treatment solution featured a solid screen and a primary


treatment system comprising of chemical dosing and dissolved air flotation (DAF). FLI CAP Technology had first carried out an extensive survey of the existing effluent treatment plant to assess condition, capacity and environmental compliance required to meet future needs. To ensure that the food manufacturing plant could consistently discharge treated effluent in compliance with the local water company’s consent parameters, the report identified that a replacement treatment plant was needed.


SPACE SAVING CRUSHER PREVENTS BLOCKING ISSUES


rom dreaded wet wipes to solids including plastics, textiles and even wood, a new Borger Multicrusher has solved long- standing blocking issues at a wastewater treatment plant. By chopping coarse material at the front-end of the treatment process, the brutish grinding of the twin-shaft Borger Multicrusher effectively protects downstream equipment, providing the site with additional resilience in to the future. Continually homogenising the medium to enhance the overall pumping process, the space-saving Borger Multicrusher at the WWTP has been installed vertically.


F


Easy to service with its simple, back-pull-out design, the Borger Multicrusher also allows very quick access to moving parts. www.boerger.com


16 JULY/AUGUST 2025 | PROCESS & CONTROL


However, no additional site space was available.


This led to FLI CAP Technology developing a detailed plan to install the new effluent treatment solution in a phased approach, in order to minimise disruption to site and maintain the facility’s operation. The 18-month project included all aspects of the design, scope of supply, M&E installation and commissioning.


Phase One saw the breaking out of the existing block chemical store and installation of new final effluent discharge sewer, plus a new ETP (Effluent Treatment Plant) building, and Dissolved Air Filtration (DAF) equipment (to be fed by the existing screen and balance tank).


During Phase Two, the existing DAF system and ETP building were removed while civil construction of new plinths for the new screen and new balance tank took place. In the third and final phase, the old balance tank and old screen gantry were removed, as were old submersible pumps, whilst new raw effluent suction pumps were installed. The new effluent treatment plant is fully automatic; controlled by a new PLC control system with colour touchscreen. Treated effluent is returned to the sewer connection via a monitoring station.


Woods concluded: “We’re seeing more and more requirements for secondary CIRIA- compliant containment. By working with Landia we have, when required, the flexibility to introduce top quality ground-mounted pumps/mixers through the tank voids as part of our overall solution. The team at Landia are always quick to respond to our needs, and we always have total confidence in their equipment.”


www.fli-captechnology.com www.landiaworld.com


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44