FLOW & LEVEL CONTROL CLAMP-ON TECHNOLOGY REDUCES WATER LOSSNOLOGY REDUCES WATER
FLEXIM explains how non-invasive clamp-on ultrasonic flowmeters are reliably measuring flow rates and
detecting leaks in water networks globally
modifications to the pipeline. They are attached to the outside of the pipe, and sound waves measure the velocity of the fluid inside. When regularly observing and comparing the minimum consumptions at night, increasing flow rates indicate potential leaks. This allows these leaks to be located and repaired quickly, reducing water loss and minimising the risk of damage to the pipeline.
U
Another advantage of clamp-on ultrasonic technology is that it can be used to optimise the flow of water through the network. Engineers are able to identify areas where the flow rate is too low or too high, and adjust it by opening or closing valves, improving efficiency and reducing energy costs.
Preventing and reducing water loss has always been an economic necessity for water companies. But with the growing challenges presented by climate change, the efficient use of this vital commodity is becoming ever more pressing.
For example, Frankfurt’s water supply has to cope with many demands in terms of both drinking water supply and consumption. The high density of jobs in the city, as well as the airport, hotels, universities, hospitals and industrial companies all add to the increased water supply requirements.
ltrasonic sensors are able to monitor water networks instantaneously, without the need for costly shutdowns or
With a keen awareness of the need to reduce water loss, the network operator of the Frankfurt energy and water supplier tasked FLEXIM with clamp-on measurement as part of their “Water network monitoring through the creation and permanent operation of flow measurements“ project. Setting up a flow measuring point in the drinking water supply network with this system would avoid the kind of considerable disruption and cost involved in the installation of a traditional wetted flowmeter, which inevitably includes inconvenient civil engineering work. Clamp-on ultrasonic transducers are simply clamped to the outside of the pipe, and do not affect the supply or risk any kind of contamination. And because the transducers used have protection class IP68, they can also be permanently operated in buried locations where ground water could submerge them (or in flooded chambers).
Because non-invasive measurement doesn’t suffer any wear and tear, there’s no maintenance involved. The robust design means flow measurement points can be set up directly in the ground – entirely omitting the time-consuming process of constructing a
RADAR LEVEL SENSOR IS EQUIPPED WITH I/O LINK ADAPTERS
EGA has launched a new radar level sensor especially for highly automated processes with stringent demands on hygiene and capable of following fast level changes. Equipped with IO-Link and versatile hygienic adapters, VEGAPULS 42 meets the key requirements of modern industry: to perform complex measuring tasks faster, be simple to use and more cost-effective. VEGAPULS 42 is designed specifically for medium measuring distances of up to 15 metres and temperatures of up to max. 150°C. The instrument is geared to circulation systems in production, dosing processes and downstream processes, like those found in conveying and filling systems. It ensures a smooth-running process wherever a level changes quickly and requires continuous monitoring. Or in short, it is tailor-made for all standard applications where more functions would only make things more complicated. In order to monitor current operating states in an efficient and cost-optimised manner, every design element of the chip was examined for its usefulness. The same principle was applied to the IO-Link communication technology, which is common in factory automation, enabling bidirectional data transmission together with extensive diagnostics and parameterisation. This means VEGAPULS 42 offers maximum signal quality at minimal cost and complexity.
www.vega.com/en-uk
V
chamber. This not only reduces the installation effort but also significantly reduces the disruption to road traffic caused by lengthy civil engineering work. With the pipeline remaining completely intact, subsequent flushing and leak testing are also unnecessary.
The greatest losses in a drinking water supply network are not caused by large burst pipes, which are noticed immediately and therefore quickly repaired, but by small leaks over a long time. These gradual losses can best be detected by recording the minimum night-time flow rates in the smallest possible network areas. If changes in the minimum flow rates are observed here, a leak can be concluded. This can then be tracked down and localised with leak detection systems.
Leakage monitoring places high demands
on the flow measurement technology used, especially with regard to measurement dynamics and accuracy, with the inertia- free acoustic measuring method being highly sensitive to even the smallest currents. Thanks to the careful pairing of the transducers in the factory and the storage of the calibration data on an integrated chip, flow measurement with ultrasonic clamp-on flowmeters does not require a zero-point calibration.
Also, being able to actually see the flow reveals processes in the water network that may not have been previously known about, from processes at the upstream network operator to hydrological abnormalities in the distribution network, along with unusual consumption behaviour by customers. Thanks to the installed flow
measurements, the water network operator now has empirical data available which can, in future, be recalibrated with the computer network model. This in turn facilitates the needs-based design of the network and optimises operational management.
FLEXIM
www.flexim.co.uk
JULY/AUGUST 2023 | PROCESS & CONTROL 15
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58