Sensors & transducers The basis for proteins that can be
used for food fortification is provided mostly by whey or skimmed milk and these need to be filtered step-by-step in order to increase protein
concentrations. The objective is to obtain a concentration with as high a protein content as possible which is then dried and further processed. This process is very energy intensive
and its effectiveness largely depends on the condition of the filter. Calorimetric flow sensors can facilitate the monitoring of the condition of the filter which helps to optimise the quality and cost-efficiency of protein extraction.
one sensor for flow rate and temPerature
Cross flow filtration technology is usually the preferred option for filter units used in the dairy industry, typically to increase the protein content in milk or whey where the media, the so called ‘feeds’, are pumped through filters until the remaining concentrate reaches the desired dry mass. An indicator of the effectiveness of the
filtration pumps (and therefore the filtration process) is usually a combination of temperature and pressure measurement. The pressure differential of the measured values before and after filtration means conclusions can be drawn about the effectiveness of the filter, such as clogging. However, would a better and more direct option not be to measure the flow rate of the medium to know for sure how the filtration process is working? For
example, if the flow rate is too low, the filter clogs up faster and needs to be cleaned or replaced. When module batteries are connected in parallel, shifts and variations in flow patterns are a problem. If the flow rate is too high, the permissible pressure loss per module is exceeded and the modules telescope. At the same time, temperature is an
important factor to consider when filtering. For example, when temperature is selected at approximately 122ºF this favours filtration without denaturation of the thermo-sensitive whey proteins which means that process temperatures must also be monitored. Thermal flow sensors, such as Baumer
FlexFlow sensors are an effective, viable and cost-effective solution for filter monitoring, as they measure not only the temperature, but also the flow rate. Since these sensors benefit from having no moving mechanical parts, they are virtually maintenance-free and allow for reliable monitoring of the cross-flow filters for many years. The Baumer FlexFlow family of flow and temperature sensors represents one of the most extensive ranges of process sensors. Based on the calorimetric measurement principle, these sensors can monitor both flow velocity as well as media temperature. They have IO-Link and, depending on
settings and connections, either two switching outputs, or one switching and one analog output (4-20 mA/ 0-10 V). The PF20H and PF20S versions are suitable for hygienic and industrial applications. The combination of two measuring
functions in one sensor reduces the number of measuring points in closed systems and minimises costs of installation, service and storage. Thanks to their symmetrical, centered design, the sensors can be optimally installed in the process independent of their installation position and orientation to guarantee precise measurements and process safety. Several sensors can be simultaneously
configured via IO-Link which simplifies switching point adjustment for different process stages during set-up or batch changeover and also saves time. Diagnostic data polling and evaluation is possible at all times, increasing system uptime. FlexFlow sensors have a robust,
stainless steel housing with integrated electronics and evaluation unit which eliminates the need for complex wiring and control cabinet assembly. Additional user interfaces, are therefore not required which simplifies operation and allows for efficient process management. All models are temperature resistant to 150°C and thus CIP (Clean-in-Place) and SIP (Steam-in-Place) capable.
ConduCtivity measurement in CiP ProCesses
Just about every cycle in dairy products processing requires CIP and this reproducible process must precisely define detergent dosing, regardless of pressure and or temperature variations. At Homanns’ CIP installations in Bottrop, dosing needed to be improved and Baumer’s new CombiLyz conductivity sensor was the solution. Thanks to fast response time it ensures precise measured results at a maximum deviation of < one per cent. The measuring connection of the inductive sensing element provides a 6.6 mm wide channel which will tolerate fabric or solid-containing media and this has helped Homann to optimise detergent dosing and reduce raw material costs. According to Frank Piatkowski,
application and process engineer at Homann, “Baumer’s CleverLevel is the one-sensor solution for different media and since deploying these sensors, we have seen a significant reduction in technical malfunctions”. He confirmed, “Baumer products will be part of our considerations when we invest in new, state-of-the-art CIP installations and we appreciate that these innovative sensing solutions help us achieve our objectives of optimization, despite the increasing complexities of our processes.”
Baumer Instrumentation Monthly February 2022
www.baumer.com/gb/en/ 41
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74