For noise at work, we might be interested in how noisy a piece of machinery or process is, and we are concerned with finding out the overall noise exposure of an individual during their working day/shift or week. This is the LEP,d (daily exposure) or LEP,w (weekly).


EXPOSURE LIMITS AND ACTION VALUES The 2005 Regulations set both exposure Action Values,


where the employer must take action to reduce noise and exposure, and Limits, which are the absolute maximum you cannot go over for both A-weighted and C-weighted noise taking into account the wearing of hearing protection.


The image here shows the Action and Limit values for A-weighted average noise of an 8hr period in dB(A). The C-weighted action levels are 135 and 137 dB(C) and the limit value is 140dB(C).


HOW TO PROTECT WORKERS First, you must measure the noise levels. You have a


choice of two measurement methods for this: a personal Noise Dosimeter and/or an Integrating Averaging Sound Level Meter.


SOUND LEVEL METERS (SLM) While a dosimeter is perfect for personal noise


measurements there are some measurements where an SLM is required. For example, if you need to know the overall noise level of a task, piece of machinery or area then you will need a sound level meter. For noise at work the legislation stipulates that you need at least a Class 2 Integrating Averaging meter to give you the data you need for compliant noise at work assessments – Pulsar’s Nova 44 Noise at Work meter is ideal for this. These meters give you the A-weighted average noise levels (LAeq) as well as LCPeak, predicted exposure and more.


If you find the overall level of noise is over 85dB(A), some form for hearing protection must be provided to bring the noise level at the ear below this. Your meter should help you choose the correct level of protection either by the HML method or by analysing the frequency content of the noise using octave band filters.


NOISE DOSIMETERS Noise dosimeters should be used when you want to find


out the direct noise exposure of an employee. Normally they are small cable-free shoulder worn devices that measure noise right at the worker’s ear, in other words, the actual noise affecting the worker. They measure both the LAeq and LCPeak values as well as calculate daily exposure levels (LEP,d). This method is particularly effective for workers with unpredictable shift patterns, those constantly on the move, or people working in confined or difficult to access areas.


twitter.com/TomorrowsHS


In summary, when you should use a sound level meter or a noise dosimeter


● Use Sound Level Meters when you need to know the noise level of a particular task or process, or how noisy a piece of machinery or area is.


● Use Noise Dosimeters when you need to find out the direct noise exposure of an employee.


Want to know more? Call: +44(0) 1723 339 715 www.pulsarinstruments.com


17


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56