Energy Management
flue gas through the stainless steel transfer media. As the water droplets travel through the media, the flue gas rises to the top of the economiser preheating the water. Final heating of the water takes place in the direct contact chamber. A transfer pump or gravity can then move the preheated water to a hot water storage system, ready to deploy to a nearby user.
Conventional heat recovery technologies require dedicated equipment for each boiler exhaust. However a single FLU-ACE®
approximately 18% of their consumed energy out of the exhaust stack, which, along with other losses from the system means that for every pound spent only 55p of energy is actually being utilised. This lost heat can be regained by using a Flu Ace®
Stack Economiser where the can handle
a varying flow of flue gases emitted from multiple boilers. This results in a lower initial investment, lower operating costs and a higher return on investment. A full payback is achieved, usually in less than two years with continuing savings being maintained throughout the unit’s 20-year plus operating life. Gas fired boilers send
boiler efficiency can then be brought up to 100%. When used in combination with the GEM Traps this reduces waste to as low as 17% providing an extra 28p of energy from every pound spent or delivering 50% more energy for your money.
With the clock ticking on the NHS to meet carbon emission targets of 15% by the end of this year, estate managers will be more than able to meet this target with steam system modernisation. This will not only have a beneficial affect on the environment but also on NHS finances, and don’t forget that every penny saved on
operating costs will enable the NHS to boost the amount it has available for front line services.
Unfortunately, when it comes to steam traps and boiler steam loss people often ignore them. This complacency is costing steam users much more than they realise. The hard reality of a plant maintaining its boiler and forgetting about the rest of the steam system can be a horribly wasteful proposition. Losses can include not only wasted energy but also replacement of damaged equipment and misuse of man-hours. Fortunately, installing low maintenance orifice venturi steam traps can avert much of these potential losses.
www.gemtrap.com
29
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56