SAFETY IN THE PLANT
G
eneral Air Products has partnered with Cortec to develop a vapour phase corrosion inhibitor (VpCi) delivery system for corrosion
mitigation of fi re sprinkler systems. General Air Products calls this new Vapor Pipe Shield “a game-changing innovation in corrosion prevention technology for dry [and] pre-action fi re sprinkler systems.” Cortec says it is excited about the opportunity it opens for facility engineers and consulting engineers to apply the benefi ts of VpCI technology to critical fi re suppression systems.
A MORE DEPENDABLE ALTERNATIVE TO NITROGEN PURGE SOLUTIONS T e Vapor Pipe Shield is a convenient, more dependable alternative to nitrogen blanketing or dried air for protection of fi re sprinklers against corrosion. It relies on Cortec VpCI technology – vapour phase corrosion inhibitors that create a protective molecular shield on the inside of the sprinkler piping system. No special equipment is required; the cartridge is compatible with standard sprinkler setups and is easy to install between the air compressor and the piping. Compressed air initially helps the vapour phase corrosion inhibitors diff use throughout all branches of the piping system to form an active layer of protection on metal surfaces. Since these vapour phase corrosion inhibitors continue to protect as long as the system remains closed, corrosion mitigation does not depend on a constant source of electricity. T at means a failed air compressor, nitrogen generator, or power source does not equal failed protection or require complete
Protecting sprinkler heads
against corrosion is critical to ensure their safe operation
FIRE SUPRESSION COLLABORATION
Harnessing technology for fi re sprinkler corrosion mitigation
reapplication. vapour phase corrosion inhibitors also protect in the presence of residual moisture and oxygen.
PATENTING, TESTING AND CERTIFICATION By drawing on its expertise in compressed air and nitrogen purge systems for fi re sprinklers, General Air
Products was able to bring to life the technology envisioned in one of Cortec’s latest patents. Vapor Pipe
Shield technology follows one of the patent’s two recommendations for distributing Cortec vapour phase corrosion inhibitors throughout the system. General Air Products reported that preliminary testing of the Cortec inhibitor treated sample showed better protection than samples treated with (1) nitrogen and (2) compressed ambient air. General Air Products also evaluated the speed of VpCI vapour migration throughout a dry sprinkler piping system test rig and determined that full distribution and protection could be achieved within one week of installation. Further validation testing continues. Most recently, the product received UL certifi cation for use in dry fi re sprinkler systems, overcoming the last major hurdle to bring Cortec’s patented technology to market.
The new Vapor Pipe Shield system
34
www.engineerlive.com
A NEW ERA FOR FIRE SUPPRESSION T is collaboration represents years of R&D used to bring technology to a market that stands to benefi t in terms of cost, convenience, and eff ective protection. It is another step forward in what may become the next big trend in fi re sprinkler protection.
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52