Efficiency


Air Quality & Ventilation Feature


In the UK we spend around 90 per cent of our time indoors and around 16 hours a day on average at home; we wouldn’t accept drinking poor quality water from our taps at home, so why should we accept breathing poor quality air?


exhaust point. The systems are typically dual speed, providing low speed continuous trickle ventilation and high-speed boost flow. Replacement fresh air is drawn into the property via background ventilators located in the habitable rooms and through air leakage. Unlike MEV, MVHR systems combine supply and extract ventilation in one


system. They work on the principle of extracting and re-using waste heat from wet rooms. MVHR systems efficiently pre-warm the fresh air drawn into the building with waste stale air using a heat exchanger; up to 95 per cent of waste heat can be recovered by this mechanism. The filtered, pre-warmed air is then distributed around the home, effectively meeting part of the heating load in energy efficient dwellings.


WAVING THE FLAG FOR MEV There’s no doubt about it, MVHR systems provide effective ventilation, are energy efficient, extremely effective at reducing the risk of condensation and cold air draughts and, with their built-in air filters, are particularly useful in more polluted urban areas. They are the champions of domestic ventilation! But MVHR systems also come with a higher price tag than their counterparts and are considerably more complex to install and commission. MEV systems, which are more affordable and straight forward, are often a more practical solution. MEV still provides excellent ventilation, but the capital costs are lower, they are easier and therefore more economical to install and operating costs are low. On the installation side, MEV systems require less ducting because air is being drawn one way only: out. With an MVHR system there is a further set of


ducting to take the air from the unit into rooms. This also has a direct impact on the level of commissioning required. Commissioning involves marrying the unit’s performance to the actual airflow passing through the valves situated throughout the property. As MEV systems have extract valves only this is a relatively straightforward process, unlike MVHR systems which must balance the extract and supply rates. The MEV units themselves are smaller and lighter than those of MVHR and


can therefore be easily wall mounted rather than in a loft. In fact, Domus Ventilation’s CMX-S MEV unit, for example, is just 125 mm deep, making it shallow enough to fit in a ceiling void. MEV systems are also very easy to use – more of a fit and forget scenario than MVHR systems which require maintenance, including regular filter changes. In the case of our own CMX-S MEV system, the optional speed and user controls enable simple operation and control for the homeowner, making them less likely to experience difficulties. Models are also available with an integral humidistat which identifies changes in humidity and automatically adjusts the air flow of the unit accordingly. With access to properties often an issue in social housing, MEV systems are often a more appealing option here. Both MEV and MVHR systems are most suitable for new properties rather


than retrofit (although that is an option in some circumstances), but MVHR systems really do require a more airtight property where virtually all of the air flow can pass through the heat exchanger, if they are to perform efficiently. Interestingly, with inner cities obviously having higher pollution levels, MVHR systems are seen as more suitable because of the filter element, but in apartment blocks it is often the case that only the first four floors are fitted with MVHR and the remaining with MEV as polluted air is heavier and therefore stays closer to the ground.


LOOKING TO THE FUTURE The issue of IAQ is finally making it onto the political agenda, which is positive news. After all, in the UK we spend around 90 per cent of our time indoors and around 16 hours a day on average at home; we wouldn’t accept drinking poor quality water from our taps at home, so why should we accept breathing poor quality air?


Penny Jones is product & marketing manager at Domus Ventilation 26 | HMM December/January 2020 | www.housingmmonline.co.uk


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40