Smoke & fire protection


With so many high-rise buildings obviously in need of upgrading, there are long term benefits in terms of both smoke control and management of the living environment to be derived from use of a SHEV system


flexibility, and the ability to operate in the event of a mains power failure. In addition, it will provide a mechanism for the fire service to stop, override, and ultimately re-set it into a different mode of operation. Factors to take into account when designing a smoke control system are far-


reaching. A mechanical smoke extraction system utilises an extract shaft so that when smoke is detected, the fire damper to the shaft on the fire floor opens while all others remain closed. The vent at the head of the staircase then opens so that a fan at the top of the shaft can extract smoke and prevent its migration into adjacent compartments. A recent innovation is the modular smoke ventilation system, an example of which is the Es-SHEV Mechanical Pod. This gives the architect or M&E consultant the guarantee of flow rate and pressure performance while offering greater ease and speed of installation. With refurbishment and new build windows so limited, a choice of sizes can be supplied pre-commissioned in a prefabricated, prewired pod, ready for a single lift to the rooftop. In terms of day to day living, overheating has become a feature of multi-


occupancy buildings. Centralised heat generation systems significantly increase temperature build-up in communal areas, a factor which, ironically, has been made worse by improved energy efficiency and air tightness standards. The secondary use of a mechanical smoke ventilation system is, therefore, becoming more common as it provides an effective means of reducing temperatures deep within a building. It does so by using the smoke shaft as a cooling chamber so that, when combined with low-level inlet air, it provides negative pressure to draw air up through the building. For the Grafton Quarter in Croydon, a £25 million project to regenerate a


former industrial site into a mixed use scheme, 97 residential units were built in which a Fire Engineer recommended a mechanical ventilation system for each


of the eight-storey blocks. The system was required to provide adjustable flow rates to run in ‘escape’ and ‘firefighting’ modes. A control system was linked to the central fire alarm and fireman priority switches were installed within the stairway on each level. During the planning phase it was also identified that the central boiler systems were constructed to run through the mechanical risers, so it was also necessary to facilitate temperature control for these areas. As a result, a fully integrated system, utilising CFD analysis, was designed within the requirements of Approved Document B and BS9991. A mechanical ventilation unit featuring integrated smoke vent louvres was installed in each building incorporating controls over floor vents plus electrical invertors to adjust extract flow rates. These adjust the fan speed and allow the system to be run at varying levels of output in the event of fire. Additional comfort fans were installed, designed to run continuously at lower speed for energy efficiency with additional dampers providing comfort ventilation for six of the eight floors in each building. The adaptive controls enable the comfort functionality to be shut down in the event of fire. With so many high-rise buildings obviously in need of upgrading, there are


long term benefits in terms of both smoke control and management of the living environment to be derived from use of a SHEV system. In terms of overall efficiency, commissioning and cost there are also advantages in the manufacturer being involved in specification and installation. Such a complete smoke extraction package ensures that, for example, uninterrupted power supplies enable a mechanical system to be installed without the requirement for two dedicated three phase power supplies. It also removes the risks associated with split sourcing of products and inadequate contracting standards, while ensuring that complementary accessories facilitate a system’s efficiency and commissioning.


www.housingmmonline.co.uk | HMM November 2018 | 49


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52