WATCH TESTING (QUARTZ)


design and small size. Included is the new Witschi feature, the computation and display of the balance wheel’s centre of unbalance.


Four different measurement methods are available to you for the quality control of mechanical watches with or without a strap. The beat noise is displayed graphically and automatic test sequences with 2 to 10 different test positions are possible. The Micromat C Service testing system with its display on your PC works with operating system : Windows 7, Windows 8 or Windows 10.


• Measures the rate accuracy, amplitude & beat error • Endless measurement, continuous diagram recording or graphic display of the beat noises


• Up to 10 testing positions manually selectable. 6 testing positions are possible for sequential (automatic) measurement


• Automatic beat selection of all common beat numbers


• Manual selection of any beat number between 3600 to 72,000 & 360,000


• Works with your existing PC with windows on a computer or tablet


• Works with operating systems: Windows 7, Windows 8 or Windows 10


• Can work with the Witschi Chronoscope X1 (any generation)


• Language selection: English, French, German, Spanish or Italian


• Replacement power adapter: M32301 • 220 to 240 Volt (if you require a different voltage, please submit an online support request under “products and stock – new item requests (excluding watch & clock parts by brand and movements)”)


 • Rate precision: +/- 0.1s/d (range +/- 999s/d) • Amplitude precision: +/- 0.4° (range 80° to 360°) • Beat error precision: +/- 0.1ms (range 0 to 9.9ms) • Vibration range: 3600 to 72,000 (& 360,000) • Lift angle: 10° to 90° (0.1° jumps) • Stabilization time: 2 seconds to 60 minutes • Measure time: 2 seconds to 300 hours • Measuring positions: 10





Click website “More Information” & “PDF’s” for full 


For service, calibration & repairs of items inside and outside of the warranty period please submit a quote request via our online support under products & stock - product advice and repairs – Witschi equipment


calibration Code


W34908 Description Witschi Micromat C System


Witschi Watch Expert (4th Generation)


UOM Price EACH £4,995.00


New watch timing & testing equipment for mechanical watches


• 4” x 1½ inch large LCD screen • Line display length: 196 dots • Will calculate the rate deviation, amplitude and beat error and display them in real time


• For professional service centres and individual workshops


• Microphone included • Made in China


New Features: • High capacitive touch screen • The results of the 6 main testing position are available in one glance


• New interactive microphone (included), control the machine from the microphone


The WATCH EXPERT is the ideal measuring instrument for testing the rate accuracy, amplitude and beat error of mechanical watches. Apart from its precision measurements and multiple measurement modes, the latest watch expert offers unique convenience at work.


Now with a high-quality capacitive touchscreen, the display of your measurement results is brilliant, high-  menus on the large colour display with four control buttons on the new microphone. The watch expert 4


 • Rate: -999 s/d - +999 s/d (Accuracy +/-1s/day) • Amplitude: 100°- 360° (Accuracy : +/-1°) • Beat error: 0 - 9.9ms (Accuracy : +/-0.1ms) • Beat (Trains): All common ones pre-programmed, others can be manually entered


• Microphone has 6 testing positions • Mains 240v • Weight 1.7kg • Dimensions: 170mm x 110mm x 500mm • 220 to 240 Volt (if you require a different voltage, please submit an online support request under “products and stock – new item requests (excluding watch & clock parts by brand and movements)”)


Code T38209 Description UOM Price Watch Timing & Testing Machine EACH £165.00 WeiShi 1000


offers watchmaking experts ergonomics, comfort and precision


• The most important results in one glance, the diagrams of all 6 main testing positions displayed in one screen (can also be displayed individually)


 display


• 7 inch capacitive touch screen works even whilst wearing cotton gloves


• Quick and easy to switch between test positions • Integrated loudspeaker for acoustic display testing of beat


• New design interactive microphone (included) • Automatic recognition of 11 testing positions • Safe and secure mount, even for heavy & large watches


• Programmable buttons on the microphone allow you to control the testing and display on the watch expert 4


• Printer = Product Code P38415 • Mains Adaptor = Product Code M32301 • Power range 100 to 240 volt (can be used either at 240 volt or 115 volt)


 • Beat number: 14 pre programmed beats or manual programming available (manual programming from 3600 to 86400)


• Beat error measurement range: 9.9ms • Rate precision: +/- 0.1s/d • Rate range: +/- 999.9s/d • Amplitude range: 70° to 360° (display possible to 999°)


• Rate resolution: 0.1sd 


For service, calibration & repairs of items inside and outside of the warranty period please submit a quote request via our online support under products & stock - product advice and repairs – Witschi equipment


calibration Code


T46232 Description Witschi Watch Expert IV


UOM Price EACH £2,195.00


New watch timing & testing equipment for mechanical watches


• 4” x 1½ inch large LCD screen • Line display length: 480 dots • Will calculate the rate deviation, amplitude and beat error and display them in real time


• For professional service centres and individual workshops


• Microphone included  • Made in China


 • Rate: -999 s/d - +999 s/d (Accuracy +/-1s/day) • Amplitude: 100°- 360° (Accuracy : +/-1°) • Beat error: 0 - 9.9ms (Accuracy : +/-0.1ms) • Pre programmed beats (Trains): 12000, 14400, 18000, 19800, 21600, 25200, 28800, 36000, 43200


• Manual selection available for other beats • Sampling periods selectable: 2, 4, 6, 8, 12, 20, 30 & 60 seconds


• Microphone has 6 testing positions • Weight 1.7kg • Dimensions: 240 x 190 x 210mm • PDF operators manual • 220 to 240 Volt (if you require a different voltage, please submit an online support request under “products and stock – new item requests (excluding watch & clock parts by brand and movements)”)


Code Description W47107 Weishi 1900


UOM Price EACH £195.00


WeiShi 1900


WATCH TEST- ING (QUARTZ)


Horotec Flashtest


An all in one ergonomic device for complete testing of quartz watches & movements


Functions: • Test battery voltage from 0 to 19.99 volts • Test battery voltage under load from 0 to 19.99 volts • Measure the coil impulse to determine if the problem is electronic or mechanical


• Measure the continuity of the coil • Test the consumption of the circuit to determine whether it needs replacing


• Fast gear train rotation to determine if the problem is a mechanical fault or if the train needs cleaning


• Measure the accuracy of the watch in seconds per day


 • LCD light screen, 29 x 23mm


www.COUSINS .COM 753


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88  |  Page 89  |  Page 90  |  Page 91  |  Page 92  |  Page 93  |  Page 94  |  Page 95  |  Page 96  |  Page 97  |  Page 98  |  Page 99  |  Page 100  |  Page 101  |  Page 102  |  Page 103  |  Page 104  |  Page 105  |  Page 106  |  Page 107  |  Page 108  |  Page 109  |  Page 110  |  Page 111  |  Page 112  |  Page 113  |  Page 114  |  Page 115  |  Page 116  |  Page 117  |  Page 118  |  Page 119  |  Page 120  |  Page 121  |  Page 122  |  Page 123  |  Page 124  |  Page 125  |  Page 126  |  Page 127  |  Page 128