DUAL TEC® GLOSSARY Environmental Adaption


Microwave thresholds are adapted either in hardware or digitally to remove the effect of low level interference such as ceiling fans.


Temperature Compensation


Sensor automatically adjusts PIR thresholds and/or other parameters to adapt to change in ambient temperature relative to human body temperature.


• Standard: Compensates at ambient temperatures below body temperature


• Advanced: Compensates at ambient temperatures both below and above body temperature


Digital Fluorescent Light Filter


Software algorithms provide infinite rejection of microwave interference due to fluorescent lights.


Analog Fluorescent Light Filter


Hardware circuitry provides rejection of microwave interferences due to fluorescent lights.


Anti-Masking


Detects intentional and accidental blocking of the PIR optics.


Walk Test Mode


Determines the coverage pattern and functionality for both the PIR and microwave channels, usually through LED indicators.


PIR Sensitivity Adjustment


Selectable option to change the PIR process sensitivity, usually through a DIP switch or jumper link.


Microwave Sensitivity Adjustment


Selectable option to change the microwave sensitivity and/or range, usually through a potentiometer.


• Form C: Three-terminal relay with both Normally Closed and Normally Open outputs when energized


LED Indicators


Light Emitting Diodes used to provide visual feedback about alarm state, supervision, walk test and other modes of operation.


• 1 LED: Single red LED


• 3 LEDs: Red, green, yellow LEDs, usually with PIR and microwave channels associated with a specific color


Microwave Supervision


Automatic self-test of microwave channel for proper operation.


Type of output relay used to signal panel when an intrusion is detected.


• Form A: Two-terminal relay with Normally Closed output when energized


Separate output used to indicate supervision failures and/or anti-mask detection to the control panel.


Alarm Relay Forms


Vertical Adjustment


Capability to adjust the vertical PIR detector position relative to the optics, usually through a vertical shift in the PCB. Usually used to adjust range at different mounting heights, or accurately set the coverage pattern for different lenses or mirrors.


Horizontal Adjustment


Capability to shift the PIR zones left or right by a few degrees. Usually used to locate potential false alarm sources, such as a heating vent between zones, or to aim the optics in a particular direction, such as a hallway.


Trouble Output


PIR Supervision


Automatic self-test of microwave channel for proper operation.


Recommended Mounting Height


Suggested height to mount processor for optimal performance. Usually important for pet immune applications.


Operating Temperature


Temperature range at which the sensor can be expected to provide adequate protection. UL certification may have a narrower range.


Input Voltage


Voltage range at the terminal strip at which the sensor will operate. UL may have certified for a slightly narrower range.


Swivel Bracket Options


Brackets used to mount sensors in installations that have special aiming or mounting heights.


55


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88  |  Page 89  |  Page 90  |  Page 91