FEATURE
Programmable alarm trips WITH IS FIELD CONNECTIONS
conditions, alarms on rate of change, and assists with or performs emergency shutdowns. Very versatile, it accepts a wide variety of signal inputs from transmitters and temperature sensors and provides dual and quad independent and individually-configurable alarm relay outputs when a monitored process variable falls outside of user-set high and/or low limits.
Key features of the SPA2 IS include:
• Intrinsically-safe field connections - Apply inputs from temperature sensors or transmitters located in hazardous areas without the need of a costly intrinsically-safe barrier. Plus power an intrinsically-safe loop using the 2-wire transmitter excitation in the current/voltage input model. • Universal plant standard - With
programmable input/output parameters and universal DC or AC power input, there’s no need to stock dozens of different alarm trips. • 20-bit input resolution - Delivers
Moore Industries has introduced the SPA2 IS with
Intrinsically-Safe (IS) Field Connections which can help process engineers reduce installation and maintenance costs
M
oore Industries announces the launch of its new SPA2
IS
programmable alarm trips with built-in intrinsically-safe (IS) field connections. Now process engineers in the chemical, petrochemical, oil & gas extraction & refining and pharmaceutical industries that monitor, control, and measure signals in hazardous areas have an alarm solution that significantly reduces wiring, installation and maintenance costs. The SPA2
trip and temperature transmitter solution that includes built-in intrinsically-safe field connections for current/voltage, resistance temperature detectors (RTDs), and thermocouples. The IS approach, as a method of hazardous area protection with monitoring and measurement instruments, is increasing globally. Many industrial sites that have previously implemented explosion- proof or flameproof protection are now utilising a hybrid approach of both protection methods in their hazardous
| INDUSTRIAL COMPLIANCE
areas. Constructing or retrofitting IS solutions within these plants can be costly and instrumentation often requires the additional purchase of a separate zener or isolating barrier and power supply.
For facilities that employ intrinsic safety measures the SPA2
IS is a cost-effective IS is a combination alarm
and complete alarm solution that includes intrinsically-safe field connections, which provides the necessary protection typically afforded by a galvanically isolated intrinsically safe barrier. In addition, the SPA2
IS cuts wiring and
maintenance costs by enabling users to eliminate additional barriers and power supplies, which reduces space requirements and heat dissipation or cooling considerations in barrier marshalling cabinets. The SPA2
IS is powered by a universal
AC/DC power supply and provides on/off control, warns of unwanted process
industry-best digital accuracy for both sensor (RTD and thermocouple) and analogue (current/voltage) inputs. • Site- and PC-programmable - Featuring security password protection, the SPA2
IS offers the choice of using
front panel pushbuttons or our FREE Windows-based Intelligent PC Configuration Software for fast and simple set up. • Large 5-digit process and status
readout - A large backlit display shows menu prompts during pushbutton configuration and, when the SPA2
operation, shows the process variable, the output, or toggles between the two in selectable engineering units. • Combined alarm trip and
transmitter - The analogue output (-AO) option reduces costs and installation time when both alarm and transmitter functions are needed at the same location. • Long-term stability - Provides up to
five years between scheduled calibrations. • Isolated and RFI/EMI protection -
Delivers superior protection against the effects of ground loops and plant noise.
Moore Industries
www.miinet.com T: 01293 514488
IS is in
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28