15
70000 Model Number Definition
U7[CC][NT]-[V][D][X) Example: U72512-1PA (contact 25, 12x1, 24vdc, diodes with common positive and SMA’s) [CC] - Contact Configuration Type
10 - Standard (normally open) 100vdc, 250ma, 10W 25 - Standard (self-terminating type, 50 ohm) 4vdc, 250ma, 1/3W 27 - Standard (self-terminating type, 75 ohm) 4vdc, 250ma, 1/3W 30 - Medium isolation (normally open) 100vdc, 250ma, 10W 40 - High isolation (normally open) 28vdc, 250ma, 3W 65 - High isolation (self-terminating, 50 ohm) 4vdc, 250ma, 1/3W 67 - High isolation (self-terminating, 75 ohm) 4vdc, 250ma, 1/3W 70 - Mercury wetted (normally open) 500vdc, 1A, 35W (Note 5) 90 - Standard with Triaxial connector (BJ77) 100vdc, 250ma, 10W
[NT] - Number of throws 02 - 2x1 04 - 4x1 08 - 8x1 12 - 12x1 16 - 16x1 24 - 24x1
[V] - Coil voltage (nominal)
1 - 24vdc to 28vdc (1000 ohm coils) 2 - 15vdc (500 ohm coils)
5 - 5vdc (135 ohm coils with NO series polarity diode included: P or N option)
[D] - Coil suppression diodes 0 - Not included
P - Suppression diodes included with coil common positive N - Suppression diodes included with coil common negative
[X] - Extra options
A - SMA signal connectors (only on contact types 10, 25, 27 & 65) F - F-Type signal connectors (only on contact types 10, 27) T - TNC signal connectors (only on contact types 10, 25, & 65) I - Insulated coaxial shield (only on contact types 10, 25, 27 & 70) S - Insulated & switched coaxial shield (only contact types 10, 25, 27, 70) L - Lockscrews on control connector so mate can be secured
U70000 NOTES:
1. The I or S options are not available on the optional signal connectors or the contact type 90 (triaxial).
2. The “expander” port is not available any longer. 3. No mating connectors or hardware are included. 4. Contact type 70 must be mounted with signal connectors facing up. 5. Due to new environmental laws, USC may or may not be able to sell relays with mercury wetted contacts. Spec was 2A, 50W. Connectors must be within 20 deg of up. 6. For installing into the U11600 chassis, the “-1” coil voltage is needed. 7. Type 27 and 67 use the standard 50 ohm MSC connector.
URS70000 NOTES:
1. The I or S options are not available on the optional signal connectors or the contact type 90 (triaxial).
2. The “expander” port is not available any longer. 3. No mating connectors or hardware are included. 4. Contact type 70 must be mounted with signal connectors facing up. 5. Due to new environmental laws, USC may or may not be able to sell relays with mercury wetted contacts. Spec used to be 2A, 50W. 7. Type 27 and 67 use the standard 50 ohm MSC connector.
RS70000 Model Number Definition
URS7[CC][NT]-[X) Example: URS71008-A (contact 10, 8x1, and SMA connectors) [CC] - Contact Configuration
10 - Standard (normally open) 100vdc, 250ma, 10W 25 - Standard (self-terminating type, 50 ohm) 4vdc, 250ma, 1/3W 27 - Standard (self-terminating type, 75 ohm) 4vdc, 250ma, 1/3W 30 - Medium isolation (normally open) 100vdc, 250ma, 10W 40 - High isolation (normally open) 28vdc, 250ma, 3W 65 - High isolation (self-terminating, 50 ohm) 4vdc, 250ma, 1/3W 67 - High isolation (self-terminating, 75 ohm) 4vdc, 250ma, 1/3W 70 - Mercury wetted (normally open) 500vdc, 1A, 35W (Note 5) 90 - Standard with Triaxial connector (BJ77) 100vdc, 250ma, 10W
[NT] - Number of throws 02 - 2x1 04 - 4x1 08 - 8x1 12 - 12x1 16 - 16x1 24 - 24x1
[X] - Extra options
A - SMA signal connectors (only on contact types 10, 25, 27 & 65) F - F-Type signal connectors (only on contact types 10, 27) T - TNC signal connectors (only on contact types 10, 25, & 65) I - Insulated coaxial shield (only on contact types 10, 25, 27 & 70) S - Insulated & switched coaxial shield (only contact types 10, 25, 27, 70)