fire testing technology limited Services
Electrical Power Control Box Fan
Scissor Lift Table
Extraction System
230 VAC at 50/60 Hz 6 Amp
Test 2: Consult FTT for details Test 3: 3PH 380-480 VAC at 50/60 Hz 16 Amp Test 4: 230 VAC at 50/60 Hz 6 Amp
Test 3: 230 VAC at 50/60 Hz 13 Amp
Test 1 & 2: Suitable extraction system is required, consult FTT for details.
Test 3 & 4: An exhaust system of 3.5 m3/sec with a duct diameter of 400mm and adjustable flow is recommended.
Hood Size (recommended)
Gas Supply
Test 3: 3m ×8m, stainless steel Test 4: 3m ×3m, stainless steel
Test 2, 3 & 4: Commercial propane 95% minimum purity is used to supply the four radiant panels.
Test 3 & 4: The required supply pressure is 3-4 bar (43.5 - 58 psi) with a suitable pressure regulator.
Compressed Air Supply
Test 2: Suitable air supply is required, consult FTT for details.
Test 3 & 4: The air supply is used to supply the four radiant panels. The required supply pressure is 6-7 bar (87-101 psi) with a suitable pressure regulator.
Water Supply
Water at 15-25° meters.
C is required for cooling the heat flux
A pressure of approximately 2.4 bar (35 psi) is recommended at a low flow rate 200-300 ml/min.
Interface Cables Brand
Please refer to instrument instruction manual for detailed requirement.
FTT do not supply any brands, please refer to standard ENV 1187 for detailed requirement.