This page contains a Flash digital edition of a book.
The Measure of Excellence 7000 Series Syringes


HAMILTON 7000 series syringes are designed on the dead volume free principle of positive displacement. A fine tungsten plunger extends through the whole length of the syringe to the needle end. These syringes are available in capacities from 0.5 µl up to 5 µl. The accuracy is ± 1% of the nominal volume. The needle and tungsten plunger are exactly fitted and can be replaced as an assembly. Since the needle length and inner diameter determine the nominal volume when ordering special needles (SN) only the length and point style can be defined. Point style 5 needles are not available.


Typical applications are:


• Sample injection in GC • Sample pipetting in the sub microliter range in GC and TLC • Micropipetting •


Animal injections • Micro volume fluid transfers


Tech Tip The knurled hub is seated against a sealing ferrule at the junction of the needle/glass barrel, to ensure injection pressure. To maintain this seal periodically tighten the knurled hub nut until light resistance to plunger movement is felt. Use of pliers on the knurled hub nut may be required to achieve tightness.


7000 Syringes Ordering information


Knurled hub (KH) pst2 Knurled hub (KH) pst3 Knurled hub (KH) pst3


Knurled hub (KH) pst *


70


100 70 *


86257 86250


* Specify only needle length, point style 5 is not available Maximum needle length for SN is 130 mm


T H E ME A S U R E O F E X C E L L E N C E TM - 18 -


80100 80108


86200 88400 88500 88000


86259


80135


86211


88411


88511


88011


Needle length mm Volume 0.5 µl


Model 7000.5 KHOC Gauge 32


Volume 0.5 µl Model 7000.5 KH Gauge 25


Volume 1.0 µl Model 7001 KH Gauge 25s


Volume 1.0 µl Model 7101 KH Gauge 22s


Volume 2.0 µl Model 7002 KH Gauge 25


Volume 2.0 µl Model 7102 KH Gauge 23


Volume 5.0 µl Model 7105 KH Gauge 24


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88  |  Page 89  |  Page 90  |  Page 91  |  Page 92  |  Page 93  |  Page 94  |  Page 95  |  Page 96