PRODUCTION • PROCESSING • HANDLING
Reliable performance W
ith decades of experience in the oil and gas industry, Lukoil, a Russian oil and gas business, aspired to expand its oil and gas
fields. For the expansion, the company selected the Bolshekhetskaya depression in West Siberia, where large deposits of Cenomanian gas lay. Developing and constructing a
compressor station to connect fields would increase the total capacity of the pipeline. Te compressor design had to produce a high discharge pressure. In addition to the pressure gain required to compensate for the piping frictional losses, the compressor’s discharge pressure would also support a refrigeration process applied to the gas at the plant outlet. Tis process, based on a throttling principle, is required to cool the gas sufficiently to avoid the buried piping temperatures from thawing the permafrost. Te permafrost helps maintain a stable support for the buried piping.
EQUIPPING THE COMPRESSORS Lukoil partnered with Sumy Frunze, an oil and gas equipment manufacturer, to develop centrifugal compressors that could withstand the frigid Siberian conditions. Te compressors would allow the station to pump 12 billion m3
of gas per year to
another station, furthering the central gas pipeline of Russia. Providing such high compressor discharge pressures with reasonable drive power requires compressors with high efficiency. Te high efficiency was achieved with
a compressor rotor shaft with a high slenderness ratio. Tis high slenderness ratio allows high efficiencies but results in a flexible compressor rotor shaft. Te Lukoil compressors have highly flexible rotors equipped with magnetic bearings. Te processing power and advanced control
34
www.engineerlive.com
IN HARSH CONDITIONS
Richard Shultz reports on how a multiple coordinate control algorithm was used to stabilise all compressor rotor natural frequencies in frigid Siberian conditions
Lukoil’s Nahodkaskaya site in Western Siberia
algorithms provided by the Waukesha Magnetic Bearings digital controller were required to make these machines a success. Waukesha’s multiple coordinate control (MCC) algorithm was used to stabilise all compressor rotor natural frequencies, with robust stability margins.
After installation, the technology
performed successfully. Within the centrifugal compressor, the magnetic bearing technology provided savings in energy and the total cost of ownership for Lukoil. Te active magnetic bearing (AMB) system has an expected life of 25 years. Te primary advantages for the end user throughout this time period are lower maintenance and operating costs and improved reliability compared to fluid film bearing solutions.
INCREASING AVAILABILITY IN HARSH CONDITIONS Te Lukoil site is located in Western Siberia, isolated from all public utilities. All electric power must be generated on site, and losing all power is not unusual. During these outages, conventional equipment such as lube oil skids, required for fluid film bearings, will drop well below operable temperatures. Te time required to heat
this equipment and the oil reservoirs back to operable temperatures can be four hours or more. Tis downtime risk was eliminated
by using magnetic bearings for the compressors. Te bearings can be reactivated within minutes after site power outages, greatly increasing the availability of the compressors. Following the 2013 installation, gas production and the total production of hydrocarbons were on track to increase by 42 billion m3
and 25%,
respectively. It is now possible for 12 billion m3
of gas to be transported from the
compressor station to the main station and ultimately to the central pipeline in Russia.
VERSATILITY Similar magnetic bearings may be used in other applications. In fact, the success of the six-stage centrifugal compressors led Lukoil to implement the Waukesha Magnetic Bearings technology on a booster compressor station in the same gas field. l
Richard Shultz is chief engineer with Waukesha Magnetic Bearings.
www.waukbearing.com
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56