is the only resistor in the circuit that varies and then only due to a change in strain on the surface.
Potential error sources In a stress analysis application, the entire gauge installation cannot be calibrated, so it is important to examine potential error sources prior to taking data.
Some gauges may be damaged during installation. It is important to check the resistance of the gauge prior to stress.
Electrical noise and interference may alter the readings. Shielded leads and adequately insulating coatings may prevent these problems.
Thermally induced voltages are caused by thermocouple effects at the junction of dissimilar metals within the measurement circuit. Magnetically induced voltages may occur when the wiring is located in a time varying magnetic field.
Temperature effects on gauge resistance and gauge factor should be compensated for as well. This may require measurement of temperature at the gauge itself, using thermocouples, thermistors or RTDs.
Prime strain gauge selection considerations are the following:
l Gauge length; l Number of gauges in gauge pattern; l Arrangement of gauges in pattern; l Grid resistance; l Strain sensitive alloy; l Carrier material; l Gauge width; l Solder tab type; l Configuration of solder tab; l Availability.
Strain gauge dimensions The active grid length, in the case of foil gauges, is the net grid length without the tabs and comprises the return loops of the wire gauges. The carrier dimensions
are designed by Omega for the optimum function of the strain gauge.
The resistance of a strain gauge is defined as the electrical resistance measured between the two metal ribbons or contact areas intended for the connection of measurement cables. The range comprises strain gauges with a nominal resistance of 120, 350, 600, and 700 Ohms.
The strain sensitivity k of a gauge is the proportionality factor between the relative change of the resistance. The strain sensitivity is a figure without dimension and is generally called gauge factor.
Temperature characteristic Temperature-dependent changes of the specific strain gauge grid resistance occur in the applied gauge owing to the linear thermal expansion coefficients of the grid and specimen materials. These changes appear to be mechanical strain in the specimen. The representation of the apparent strain as a function of temperature is called the temperature characteristic of the strain gauge application. To keep apparent strain through temperature changes as small as possible, each gauge is matched during the production to a certain linear thermal expansion coefficient. Omega offers strain gauges with temperature characteristics matched to ferritic steel and aluminium.
The maximum values quoted are only permitted for appropriate application on materials with good heat conduction if room temperature is not exceeded. In other cases, temperature rise in the measuring grid area may lead to errors. Measurements on plastics and other materials with bad heat conduction require the reduction of the energising voltage or the duty cycle. l
For more information ✔ at
www.engineerlive.com/asia
For more information visit www
www.engineerlive.com 19
.sea.omega.com
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39