THE SOURCE TESTING ASSOCIATION ANNUAL GUIDE 2011
Acronyms and abbreviations ICP ICPCR
IED IMS IPA IPC
IPPC IR
ISC ISE ISO
iTEQ JRC
LAAPC LAQM LAU
LCPD LOD
LTRAP MCERTS MDHS MID MM5 Inductively coupled plasma (spectroscopy)
Ion chromatography with a post column reactor – analytical technique specifically for hexavalent chromium
Industrial emissions directive Ion mobility spectrometry Isopropyl alcohol
Integrated pollution control
Integrated pollution prevention and control Infrared
Intersociety Committee Ion-selective electrode
International Standards Organisation International toxic equivalent quantity European Joint Research Centre Local authority air pollution control Local air quality management
Environment Agency Local Authority Unit Large combustion plant directive Limit of detection
Convention on long-range transboundary air pollution
The Environment Agency’s monitoring certification scheme
Method for the Determination of Hazardous Substances
Method implementation document – developed by EA and STA on how to apply standards in the UK
USA Modified Method 5 – extractive adsorbing emission sampling train for the measurement of volatile organic compounds, usually toxic or hazardous compounds, with boiling points over about 130oC
MS
MSW MWC MWI
NDIR NDUV NECD NEN
NIOSH NIST
Mass spectrometry Municipal solid waste
Municipal waste combustor
Medical waste incinerator or municipal waste incinerator, refer to WID
Non-dispersive infrared spectrometry Non-dispersive ultraviolet spectrometry National Emission Ceilings Directive Netherlands standardisation institute
National Institute of Occupational Safety and Health (USA)
USA National Institute for Standards and Technology – US Federal organization responsible for evaluating and setting performance and design standards for measurements (formerly NBS)
NMOC
Non-methane organic compounds organic compounds other than methane
18 Source Testing Association Annual Guide 2011 QC
ROG Rsd RTP
SCD SCR
SD
SED SEM
Semi-VOST
NMVOCs NOx
NPL OES
OMA OPM
OSHA OU PAHs
PCBs PIC PID PM
PM10, PM2.5
POM PPC
Regulations prEN PUF QA
QAL1 QAL2 QAL3
Non-methane volatile organic compounds Oxides of nitrogen – by convention taken
to be the sum of NO and NO2 (excluding N2O and other nitrogen oxides)
UK National Physical Laboratory – the UK’s National Measurement Institute
Optical emission spectroscopy Operator monitoring assessment
Open path monitoring system (long path monitoring)
Occupational Safety and Health Administration (USA)
Odour units
Polynuclear aromatic hydrocarbons, also known as poly-aromatic hydrocarbons and polycyclic aromatic hydrocarbons
Polychlorinated biphenyls
Product of incomplete combustion Photo-ionisation detector Particulate matter
Particle fraction with diameter less than 10 µm or 2.5 µm
Polycyclic organic matter – includes benzene and related compounds often in particulate form at ambient conditions
Pollution prevention and control regulations
Draft European standard Polyurethane foam Quality assurance
Quality assurance level 1 – AMS as tested to the requirements CEN standard EN15267 or MCERTS CEM systems
Quality assurance level 2 – calibration of an AMS in accordance with CEN standard EN14181
Quality assurance level 3 – on going performance of an AMS is accordance with CEN standard EN14181
Quality control Reactive organic gases Relative standard deviation
Research Triangle Park, NC, USA – location for several USA EPA Program offices
Sulphur chemiluminescence detector
Selective catalytic reduction – NOx control technique
Standard deviation
Solvent emission directive Scanning electron microscopy
Semi-volatile organic compounds sampling train – see MM5
WG WHO WHO-TEQ WID TEF
TEOM TEQ TGN THC TPM TRS TSP
TVOC UKAS
US EPA US EPA CT UV UV-DOAS VDI VOC VOST
SEPA SOx SRM SSP STA
TC
TCDD TCDF TD
TDL TE
Scottish Environment Protection Agency Oxides of sulphur
Standard reference method Site-specific protocol
Source Testing Association – technical trade association representing companies with an interest in emission monitoring
Technical committee as referred to in standards organisations e.g. CEN
Tetrachlorodibenzodioxin Tetrachlorodibenzofuran Thermal desorption Tuneable diode laser
Technical endorsement as referred to in MCERTS performance standard for personnel
Toxic equivalent factor
Tapered element oscillating microbalance Toxic equivalent quantity Technical guidance note Total hydrocarbons.
Total particulate matter Total reduced sulphur
Total suspended particulate matter Total volatile organic compound United Kingdom Accreditation Service
United States Environmental Protection Agency
United States Environmental Protection Agency Conditional Test
Ultraviolet
Ultraviolet dual optical absorption spectrometry
Verein Deutscher Ingenieure (German national standards body)
Volatile organic compound
Volatile organic sampling train - extractive adsorbing emission sampling train for the measurement of volatile organic compounds, usually toxic or hazardous compounds, with boiling points up to about 130oC. Analysis of sample is by GC/MS
Working group as referred to in standards organisations e.g. CEN
World Health Organisation
World Health Organisation toxic equivalent quantity
Waste incineration directive
XAD/XAD-2 Trade name for a polystyrene adsorbent resin
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44