MODULAR COOLING SOLUTION Hitachi has developed the refrigerant Natural Circulation system (NC system), saving energy by eliminating the need for a power source to drive operation.
NATURAL CIRCULATION – THE BESPOKE
THE TECHNOLOGY Hitachi’s NC system requires no pump or
compressor. The heat from the server vaporises the refrigerant, causing it to rise. When cooled, it condenses and falls. Utilising these rising and falling streams, the system circulates the refrigerant without an externally powered driving force.
NC RACK Half the width (300mm) of standard server racks, rack type air conditioners takes up far less space than conventional models, providing 22kW of cooling capacity. The warm air from the server is exhausted to the back of the rack where it is sucked in by the adjacent rack type air conditioner. It is cooled and vented to the front as a stream of chilled air, which the server then takes in creating a cooling cycle.
NC DOOR Rear door cooling units attach to the back of server racks to provide 10kW of cooling capacity. The air conditioner directly takes the
heat exhausted from the server and rejects it at optimal room conditions, allowing a high degree of server integration.
SCALABLE AND FLEXIBLE Easy integration to new and existing facilities provide customers with a tailor-made solution as Hitachi recognises the necessity for bespoke answers to data centre needs.
GREEN DATA SYSTEM (GDS) Hitachi delivered and installed the NC system at GDS in Deventer, Netherlands in July. The modular based Hitachi NC cooling solution has been housed at this Deventer site, showcasing the first of the new technology available to customers throughout continental Europe.
Wessel Graatsma, CEO of Green Data Systems, said “Among all the solutions we looked at, the Natural Circulation system by Hitachi promised to fulfill all our requirements. Designed on demand to fit our needs, the solution was installed only a short
time ago, but we are already seeing positive results. The Natural Circulation system does exactly what Hitachi promised and we are looking forward for the first full evaluation once the system has been up and running for a longer period.”
DATA CENTER DYNAMICS LONDON 2010 Visit Hitachi’s NC system at DCD’s London event on November 9th and 10th and find out where else we’ve delivered our solution and how it can benefit you.
CONTACT INFORMATION
For more information visit:
http://www.hitachi.eu/edc
or contact: Ian Blond +44 (0)776 524 2354
Alternatively, email:
edc@hitachi-eu.com
NC Rack
NC Installation at GDS
NC Door
www.datacenterdynamics.com
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80 |
Page 81 |
Page 82 |
Page 83 |
Page 84 |
Page 85 |
Page 86 |
Page 87 |
Page 88 |
Page 89 |
Page 90 |
Page 91 |
Page 92 |
Page 93 |
Page 94 |
Page 95 |
Page 96