ADVERTORIAL MINKELS


VISION OF MINKELS


“Choice of datacenter solution determined not by fl oor area but by volume” Minkels’ approach leads to operational excellence in datacenter operations


The choice of a datacenter cooling solution is often driven by the available number of square metres or the energy density per rack. The approach taken by Minkels, with datacenter volume (m3) as its starting point, leads faster to the most suitable solution for any specifi c situation.


“The traditional approach tends to limit your options and often paves the way for wrong choices or extended implementation projects,” says Jeroen Hol, Chief Commercial Offi cer (CCO) of Aegide Group, the parent company of Minkels. “Our approach, which is based on the datacenter volume, ultimately leads to a superior solution.”


While limitations in the volume of a datacenter room barely play a role in completely greenfi eld data centres, around 90% of datacenter building involves modifi cations to existing datacenters or the installation in confi ned spaces.


“Ideally a datacenter should be completely cooled with air,” says Hol. “Preferably via a method such as Free Cooling, thus cooling with the aid of the outdoor temperature, which of course all depends on local temperatures. If you’ve got plenty of volume, then there is no need at all to consider water cooling. Air is practically always the best solution in that case.”


“Corporate datacenters are often established in the basements of a company, and every space is diff erent. Most datacenters are thus by no means ideal. In such situations it is also important to take the volume as starting point .”


A combination of cooling by air and water may sometimes be the most practical alternative. “From a thermodynamic point of view, however, it is always better to have a single heat transfer regime,” says Hol. “The addition of a second cooling circuit means there are two heat transfer moments, each of which leads to heat loss. This option should therefore only be considered when absolutely necessary.”


Cooling can also take place at chip level. In that case the volume of a datacenter pays no role whatsoever. Hol: “At present, only 2% of the servers worldwide are cooled at chip level. What’s more, it will take several decades before all the technology in a datacenter, including switches and routers, is suitable for chip cooling.”


No matter what cooling solution you choose, appropriate monitoring is essential to achieve operational excellence in datacenter operations.


LAUNCH MINKELS VARICONTROL 1.0 True effi ciency in a datacenter can only be realised with the support of a sound datacenter monitoring solution. This will enable you to optimise performance and eff ectively reduce energy consumption, for example. Minkels has, with this in mind, developed Varicontrol 1.0, an intelligent software solution for measuring, monitoring and managing physical datacenters.


Varicontrol 1.0 is extremely user-friendly, especially as it is an open platform, suitable for the simultaneous management of physical datacenter infrastructures of both Minkels and other brands.


MINKELS DATACENTER SOLUTIONS The R&D department of Minkels has developed a variety of datacenter solutions in the fi eld of housing, cooling and monitoring. • Air cooling: Varicondition® Cold Corridors • High density cooling: Varicondition® H2O and Varicondition HD (air) • Monitoring: Varicontrol® 1.0 • Datacenter housing: Varicon®


Datacenter rooms vary in volume (m3). For an optimal datacenter architecture, go to:


www.minkels.com/virtualdatacenter. WATER Varicondition H20 Varicondition DX DX m³


For further information on the datacenter solutions of Minkels, mail to: info@minkels.com. Or call +31 (0)413 311 100 (Netherlands), or: +32 (0)16 44 2010 (Belgium), or: +41 (0)41 748 4060 (Switzerland), or: +44 (0)1494 451706 (UK), or: +33 (0)164 616191 (France).


Varicondition HD Varicondition FRESH AIR AIR COLD CORRIDOR


www.datacenterdynamics.com


67


kW


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88  |  Page 89  |  Page 90  |  Page 91  |  Page 92  |  Page 93  |  Page 94  |  Page 95  |  Page 96