This page contains a Flash digital edition of a book.
Load/Life Data Components used in the Simple-Select® range will provide the user with the best combination to achieve a long


and trouble free life in clean or arduous environments. Fitted cap seals cover double row bearings and provide a reservoir for grease lubrication and to prevent dirt ingress. In most cases a single application of grease, which Bishop-Wisecarver provides on assembly of the unit, will last for the life of the machine.


Simple Life Check


Most applications involve central L1 loads. In these cases simply divide your load (N) by the carriage L1 capacity figure below to determine a load factor. Then simply read off the life from the graph. For offset loads you will need to add the relevant load factors to determine the total. Load Factor should not exceed 1.


L1 M MS


L2 Carriage Capacities


Size 20 25 44 76


L1(N) 435 800


2800


L2(N) Ms(Nm) Mv(Nm) M(Nm) 685


1500 4700


10000 10000


4 9


57 360


19 56


243 990


12 30


146 990


MV


Load Factor =


Carriage Capacity = Load Carried


L1 L1(max)


+


L2 L2(max)


+


Ms Ms(max)


+


Mv Mv(max)


+


M M(max)


1,000,000


100,000


Life (km)


10,000


1,000


100 0 0.25 0.5 Load Factor 3 0.75 1.0


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8
Produced with Yudu - www.yudu.com