Load/Life Data Components used in the Simple-Select® range will provide the user with the best combination to achieve a long
and trouble free life in clean or arduous environments. Fitted cap seals cover double row bearings and provide a reservoir for grease lubrication and to prevent dirt ingress. In most cases a single application of grease, which Bishop-Wisecarver provides on assembly of the unit, will last for the life of the machine.
Simple Life Check
Most applications involve central L1 loads. In these cases simply divide your load (N) by the carriage L1 capacity figure below to determine a load factor. Then simply read off the life from the graph. For offset loads you will need to add the relevant load factors to determine the total. Load Factor should not exceed 1.
L1 M MS
L2 Carriage Capacities
Size 20 25 44 76
L1(N) 435 800
2800
L2(N) Ms(Nm) Mv(Nm) M(Nm) 685
1500 4700
10000 10000
4 9
57 360
19 56
243 990
12 30
146 990
MV
Load Factor =
Carriage Capacity = Load Carried
L1 L1(max)
+
L2 L2(max)
+
Ms Ms(max)
+
Mv Mv(max)
+
M M(max)
1,000,000
100,000
Life (km)
10,000
1,000
100 0 0.25 0.5 Load Factor 3 0.75 1.0