Members of the sub-committees are Governmental Departments or Services, Non Governmental Organisations (NGOs), the Technical Chamber, Associations and other parties involved in the building sector appointed by the Law for the Regulation of the Energy Performance of Buildings of 2006, L.142(I)/2006. Their duty is to advise the Minister of Commerce, Industry and Tourism for the preparation of the methodology for the calculation of the energy performance of buildings and its revisions, for the setting of the minimum requirements and their revisions and for the correct and proper implementation of the directive and its transposition to the national legislation.

Since the 21st of December, 2007 two ministerial orders regarding the methodology for the calculation of the energy performance of buildings and the minimum requirements for the energy performance of buildings have been published, enforcing part of the Law for the Regulation of the Energy Performance of Buildings of 2006, L.142(I)/2006.

As a first step, the minimum requirements set for the energy performance of buildings are restricted to the insulation of the envelope, and are shown in the table below.

Table 1: Minimum requirements for the energy performance of all new buildings and buildings exceeding 1000 m2 of total useful floor area undergoing major renovation.

U – Description

Horizontal structural elements of the shell.

Walls and structural elements of the shell.

Windows

Floor in contact with unheated spaces

value (W/m2K)

≤ 0.75 ≤ 0.85 ≤ 3.8 ≤ 2

Comments

Not applied to passive systems

Not applied to shop windows

At this stage the above minimum requirements apply for all new buildings and buildings exceeding 1000 m2 of total useful floor area undergoing major renovation regardless of their location.

2 > Status of the implementation

The enactment of the legislation concerning the minimum energy requirements for all new buildings and existing buildings exceeding 1000 m2 total useful floor area undergoing major renovation has been in force since the 21st of December 2007. Major renovations comprise those buildings where the total cost of the renovation related to the building shell and/or energy installations such us heating, hot water supply, air- conditioning, ventilation and lighting is higher than 25% of the value of the building, excluding the value of the land upon which the building is situated, or those where more than 25% of the building shell undergoes renovation. As a result of this enactment, the designer of a building, when submitting an application for a building permit, should submit to the local authorities a set of the energy performance calculations proving compliance with the minimum requirements published by the Minister.

For this purpose the MCIT has prepared a guidance document concerning the thermal insulation of buildings and developed a simple calculation tool for the calculation of the U values of the elements composing the building shell. Both the guide and calculation tool, are available on the Ministry

EPBD Buildings Platform > P130_EN_Cyprus_June2008

Page 45

2 Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88  |  Page 89  |  Page 90  |  Page 91  |  Page 92  |  Page 93  |  Page 94  |  Page 95  |  Page 96  |  Page 97  |  Page 98  |  Page 99  |  Page 100  |  Page 101  |  Page 102  |  Page 103  |  Page 104  |  Page 105  |  Page 106  |  Page 107  |  Page 108  |  Page 109  |  Page 110  |  Page 111  |  Page 112  |  Page 113  |  Page 114  |  Page 115  |  Page 116  |  Page 117  |  Page 118  |  Page 119  |  Page 120  |  Page 121  |  Page 122  |  Page 123  |  Page 124  |  Page 125  |  Page 126  |  Page 127  |  Page 128  |  Page 129  |  Page 130  |  Page 131  |  Page 132  |  Page 133  |  Page 134  |  Page 135  |  Page 136  |  Page 137  |  Page 138  |  Page 139  |  Page 140  |  Page 141  |  Page 142  |  Page 143  |  Page 144  |  Page 145  |  Page 146  |  Page 147  |  Page 148  |  Page 149  |  Page 150  |  Page 151  |  Page 152  |  Page 153  |  Page 154  |  Page 155  |  Page 156  |  Page 157  |  Page 158  |  Page 159  |  Page 160  |  Page 161  |  Page 162  |  Page 163  |  Page 164  |  Page 165  |  Page 166  |  Page 167  |  Page 168  |  Page 169  |  Page 170  |  Page 171  |  Page 172  |  Page 173  |  Page 174  |  Page 175  |  Page 176  |  Page 177  |  Page 178  |  Page 179  |  Page 180  |  Page 181  |  Page 182  |  Page 183  |  Page 184  |  Page 185  |  Page 186  |  Page 187  |  Page 188  |  Page 189  |  Page 190  |  Page 191  |  Page 192  |  Page 193  |  Page 194  |  Page 195  |  Page 196  |  Page 197  |  Page 198  |  Page 199  |  Page 200  |  Page 201  |  Page 202  |  Page 203  |  Page 204  |  Page 205  |  Page 206  |  Page 207  |  Page 208  |  Page 209  |  Page 210  |  Page 211  |  Page 212  |  Page 213  |  Page 214  |  Page 215  |  Page 216  |  Page 217  |  Page 218  |  Page 219  |  Page 220