Electrical connections EC
K3)
Technicalfeatures:
• PFC (passive)
• Control input 0-10VDC / PWM
• Output 10VDC (±20 %) max.10 mA
• Alarm relay
• Electronics / motor overtemperature protection
• Line undervoltage / phase failure detection
• Motor current limitation
• Locked-rotor protection,soft start
Notes on various control possibilities and their applications
U
min
= 15V
L1
I
max
=
black +
10 mA
Mains L2
50/60 Hz
L3
black
black
-
PE
green/yellow
NC
white1
Alarm relay:
+ COM
Break for failure
(2A,250VAC,AC1)
PWM
U white2
10 K
-
Voltage output
red +10V
12V
max.10 mA
Lin/PWM control input
yellow 0-10VDC /
PWM
1µF
GND
blue
Speed setting Speed setting Full speed Speed setting
with variable
PWM 1 - 10 kHz
resistance
1V - 10V
100% PWM -> n=max 10V -> n=max
approx.10% PWM ->n=min approx.1V -> n=min
< 10% PWM -> n=0 < 1V -> n=0
start up at > 14% start up at > 1,4V
Customercircuit Connection Fan
Line1 Line2
V V
L1 L2 L3 PE NC
COM
+10 0-10
PWM GND
black black black green/yellow white1 white2 red yellow blue
Line Connection Colour Assignment/function Line Connection Colour Assignment/function
1 L1 black Mains; L1 2 +10V red Voltage output +10V max.1.1 mA
L2 black Mains; L2 0-10V / PWM yellow Control input (Impedance 100 kΩ)
L3 black Mains; L3 GND blue GND
PE green/yel Protective earth
NC white1 Alarm relay,break for failure
COM white2 Alarm relay,COMMON
39
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48