EARTHING CONDUCTIVE CONCRETE: CONDUCRETE®
SummaryofConducrete®’s EnvironmentallyNeutral/pHNeutral
KeyFeaturesandBenefits
•Conducrete® has no negative impact on the environment. In fact, it has
1.Protectsearthing/groundingsystemsfromtheftandsabotage
been approved for use by regulatory agencies in many environmentally
2.Environmentallyneutral
sensitiveareaswhereaquifercross-contaminationisaconcern.
3.Significantlyextendsthelifeofearthing/groundingsystems
•Conducrete® is water impermeable and pH neutral when set up and will
4.Dramaticallyenhancestheperformanceofearthing/groundingsystemsfor
notcorrodecopperconductors.
superiorelectricalandlightningprotectionforyourassets
•Nosaltswillleachinto,orcontaminate,thesoil.Leachatetestingshowsthat
5.Excellentoverallvalue
Conducrete®haslevelsfarbelowacceptableleachatelimits.
6.The knowledge that your site shares the same standard as an array of
prestigiousstructuresaroundtheworld.
LongLifeExpectancy
•Independent testing indicates that Conducrete® can reduce
TheftResistantandMaintenanceFree
electrolytic corrosion.
•Conducrete®protectstheunderlyingearthing/groundingsystemfromtheft
•Conducrete®canextendthelifeofearthing/groundingsystemsbyafactor
and sabotage. Theft is increasingly becoming a pervasive problem world of 10. Electrodes protected by Conducrete® will last far in excess of 25
wide,whichsubstantiallyincreasesthecostsfromthelossofmaterialand yearsinmanycases.
outages. Because Conducrete® solidifies into a high strength conductive
concrete,thelikelihoodofsuchissuesissubstantiallyreduced.
•Conducrete®electrodesaremaintenance-freeovertheirfunctionallifetime.
CompressiveStrengthandLowShrinkage
TherearenohydrationorsaltreplacementrequirementswithConducrete®. •Conducrete® has a compressive strength of 21MPa (3045 psi) after 28
days. This means that Conducrete® electrodes are permanent, will not
washawayandwillwithstandheavyearth/groundfaultcurrents.
•Conducrete® testing yields shrinkage of 0.015% at 28 days. This means
that Conducrete® bonds or knits to the surrounding soil resulting in a
superiorelectrodeduetotheconstantcontactwiththesurroundingsoil.
HighVoltage/CurrentTestResults
InindependenttestinginahighvoltagelabprecastConducrete®electrodes
withstood 1682V/688 amp fault for a duration of 500ms. Other
earthing/grounding enhancement materials of lower compressive strength
haveexplodedunderthesetestconditionswhichwouldrendertheprotection
systemuseless.Conducrete®istheonlyearthing/groundingbackfillthathas
documentedevidenceofhighfaultcurrentwithstand.
18 a4 +44 (0)115 975 7600
www.fmsudafix.com
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80 |
Page 81 |
Page 82 |
Page 83 |
Page 84 |
Page 85 |
Page 86 |
Page 87 |
Page 88 |
Page 89 |
Page 90 |
Page 91 |
Page 92 |
Page 93 |
Page 94 |
Page 95 |
Page 96 |
Page 97 |
Page 98 |
Page 99 |
Page 100 |
Page 101 |
Page 102 |
Page 103 |
Page 104 |
Page 105 |
Page 106 |
Page 107 |
Page 108 |
Page 109 |
Page 110 |
Page 111 |
Page 112